CDB650-204
PNP sensor
3
V
S
GND
12
SGND
6
Shield
11 U
IN
*
A
Out
U
IN
*
GND
S3
Trigger sensor
1
ON
OFF
S3 : SGND-GND
V
S ext
Shield
U
IN
*
CDB650-204
12 SGND
6
Shield
11 U
IN
*
A
GND
S3
ON
OFF
S3 : SGND-GND
Shield
1
V
S ext
GND
A
12
2
SENS/IN
B
SENS/IN
B
2
2
4
Figure 25: Left: Trigger sensor connected potential-free and supplied with power externally. Right: Alternatively switch,
!
sup‐
plied with power by connection module CDB650-204 or
"
connected potential-free and supplied with power externally. Switch
setting S3 then as in left figure.
1
Trigger sensor, e.g. for read cycle generation
2
External supply voltage V
S
ext
3
PNP sensor
4
Supply voltage V
S
Table 20: Assignment of placeholders to the digital inputs
CDB650-204
Device
Terminal A
Signal B
Pin C
Sensor D
10
SENS/IN 1
10
1
13
SENS/IN 2
15
2
Function of switch S3
Table 21: Switch S3: SGND - GND
Switch setting
Function
ON
GND of the trigger sensor connected with GND of CDB650-204 and
GND of the device
OFF
Trigger sensor connected potential-free at CDB650-204 and device.
Common, isolated reference potential of all digital inputs is SGND.
Characteristic data of the digital inputs
Table 22: Characteristic data of the digital inputs “Sensor 1” and “Sensor 2”
Type
Switching
Switching behavior
Power to the input starts the assigned function, e.g. start read cycle.
Default setting in the device: logic not inverted (active high), debounce
time 10 ms
Properties
•
Opto-decoupled, reverse polarity protected
•
Can be wired with PNP output of a trigger sensor
Electrical values
Low: V
in
1)
≤ 2 V; I
in
2)
≤ 0.3 mA
High: 6 V ≤ V
in
≤ 30 V; 0.7 mA ≤ I
in
≤ 5 mA
1)
Input voltage.
2)
Input current.