Ruler E
Encoder Wire Diagram
E
Encoder Wire Diagram
When external synchronization signals are used these should be connected to the Encoder
connector according to the following wire diagram.
Warning
Never connect any signals while the Ruler unit is powered.
Never connect a powered I/O & Encoder Interface unit to a Ruler.
Never connect anything but TTL signal levels
ailure to follow these rules may damage the Ruler unit.
F
Each Ruler E is delivered with an Encoder cable. This cable has a M12 plug in one end and
is open in the other.
Table E.3 – Ruler E to SICK Stegman Encoder wire diagram
%
WARNING
Ruler E
SICK Stegman Encoder
Pin
Color*
Signal
Pin
Color
Signal
1 White
In1
+
8
Pink
A+
2 Brown
In2
+
5
White
B+
3 Green
In2
-
6
Brown
B-
4 Yellow
In1
-
1
Black
A-
5 Gray
GND
10
Blue
GND
6 Pink
-
7 Blue
In4
8 Red
Out
2
*Color is valid for cable type STL-1208-
SICK IVP • Industrial Sensors • www.sickivp.com • All rights reserved