S400 S600 Operator Manual 2009
Supreme Sander
15
TROUBLE SHOOTING
LOST OF SUCTION IN DUST COLLECTION
1.
Dust drawer may be full. Empty it.
2.
Blower fan may be clogged. Clean it.
BELT CREEPS
1.
Belt worn out or frayed one side. Install new belt.
MOTOR STOPS WITH SWITCH ON
CAUTION: Turn switch off immediately.
1.
Too much equipment operated on same circuit on which Supreme
S400/S600 Sander is connected. Check circuit breaker or fuse box.
2.
An overload may have caused the thermal overload protector in motor to
shut off current. Be sure sander is off, then find and eliminate cause for
overload. On motor equipped with automatic thermal overload protector
wait approximately 5 minutes, then turn switch back on. Repeat in one
minute if motor does not come on. On motor equipped with manual Re-
Set thermal overload protector wait at least 15 minutes, then firmly press
Re-Set button on motor with eraser end of pencil or a small blunt dowel.
After approximately 30 minutes you should be able to hear or feel overload
protector click in when pushed to reset. After Re-Set clicks in, turn switch
on and motor should run normally.