7 | Spark-100 HW user manual v1.3
Figure 2 – SOM internal power scheme
The SOM uses both fixed and configurable power converters for powering the HPS and FPGA IO banks.
The following table describes the power levels of available for each I/O bank:
FPGA IO banks:
FPGA bank
Number of I/O
Voltage supported
Remarks
Bank 3A
16
1.8V or 3.3V
The default configuration 1.8V.
For other options contact
Bank 3B
32
1.5V, 1.8V, 2.5V, 3.3V The selection is done by hardware
and cannot be changed during
operation.
Bank 4A
68
1.5V, 1.8V, 2.5V, 3.3V The selection is done by hardware
and cannot be changed during
operation.
Bank 5A
16
1.8V
Fix
Bank 5B
7
3.3V
Fix
Bank 8A
6
1.8V
Fix
HPS IO banks:
HPS bank
Voltage supported
Remarks
Bank 6
1.5v
Internal bank for DDR
7A
1.8V
Various interfaces,
7B, 7C
3.3V
Various interfaces, like SD and USB
2.1.3
Bank 3B and 4A - Programmable Power levels
The power of banks 3B and 4A can be programmed according to the design requirements. Each bank in
the FPGA has a VCCPD and a VCCIO that control the banks power level. Banks 3B and 4A share a single
Summary of Contents for Spark-100
Page 1: ...Spark 100 Altera Cyclone V SOC System on Module Integration guide Revision 1 3...
Page 35: ...35 Spark 100 HW user manual v1 3 Clock configuration...
Page 36: ...36 Spark 100 HW user manual v1 3 DDR setting...
Page 37: ...37 Spark 100 HW user manual v1 3...
Page 38: ...38 Spark 100 HW user manual v1 3...
Page 39: ...39 Spark 100 HW user manual v1 3...