- 31 -
•
When removing waste liquid from the equipment, place some container to collect
the liquid and prevent it from spilling on the ground. Dispose of such oil, fuel,
cooling water (LLC), filters, batteries and other harmful substances as industrial
waste in accordance with applicable laws and regulations. Consult with the retail
outlet where the equipment was purchased if you have any inquiries regarding
proper disposal.
•
When performing maintenance with doors or covers open, be sure that no other
persons can accidentally come close to the equipment. Close all doors and
covers if momentarily leaving the equipment unattended.
Perform periodic inspection and maintenance as indicated by the table below in
order to ensure that this equipment can be operated in optimal condition.
Use the hour meter as a general indicator for the operating time.
Inspection Item
Pre-
Operation
Inspection
Inspection Period
50th
hour
Every 100
hours
Every 200
hours
Every 400
hours
Every
1,000
hours
Every
2,000
hours
1 Inspect/Add Fuel
2 Inspect/Add Engine Oil
3 Change Engine Oil
1st time
2nd time
and after
4 Change Oil Filter
1st time
2nd time
and after
5
Inspect/Add Cooling
Water
6 Change Cooling Water
or
1
year
7 Clean Fuel Filter
1st time
2nd time
and after
8 Replace Fuel Element
9
Inspect Water
Separator
10
Drain Water from/Clean
Water Separator
11
Drain Water from/Clean
Fuel Tank
12
Inspect for
Fuel/Oil/Cooling Water
Leakage
13
Inspect/Add Battery
Fluid
14 Clean Air Element
1st time
2nd time
and after
15 Replace Air Element
16 Adjust V-belt Tension
1st time
2nd time
and after
17 Replace V-belt
or
2 years
18
Clean Radiator Fin
(External)
19
Clean Radiator
(Internal)
Summary of Contents for DGW500DM