- 19 -
■
Battery Replacement Procedures
1) Remove the "
-
" (negative) cable.
(Always be sure to first remove the
"
-
" (negative) side.)
2) Remove the battery hold-down clamp.
3) Remove the "+" (positive) cable.
4) Remove the battery.
* Install the battery by performing the above procedures in reverse order. (Always
be sure to first attach the "+" (positive) side.)
<Note>
•
Use the specified battery.
<75D31R> (Japanese Industrial Standard)
Warning: Suffocation from Exhaust Fume
•
Do not operate the equipment in a poorly-ventilated area such as indoors or
within a tunnel because the engine exhaust fume includes components that are
harmful to humans.
Warning: Fire
•
Keep any ignitable items (such as fuel, gas and paint) or inflammable items away
from the equipment because the muffler, exhaust fume and other parts attain high
temperatures.
•
Provide at least 1 meter (3 feet) of distance between the equipment and walls and
other obstacles, and operate the equipment on a flat surface.
Caution: Suffocation from Exhaust Fume
•
Do not direct the engine exhaust towards passersby, private homes or similar
persons/locations because the engine exhaust fume includes components that
are harmful to humans.
Caution: Burn
•
The engine, muffler and similar parts are extremely hot during operation and
immediately after stopping the equipment. Never touch hot parts.
Caution: Injury
•
Use this equipment with it situated on a stable level surface so that it is prevented
from moving.
•
Do not move the equipment during operation.
•
Always be sure to turn off the switches of all devices using the equipment and
turn off the equipment breakers before starting the engine.
<Note>
•
Check that the surrounding area is safe before starting the engine.
•
When there are multiple workers who are working together, they must mutually
signal each other before starting the engine.
•
Do not use in an area with high temperature or humidity, or an area with a large
amount of dust.
•
Do not open any doors during operation. Operating with a door open can
negatively affect cooling effect, resulting in an equipment malfunction.
•
Use ear protection if the level of noise is high. Failure to do so could result in
hearing damage.
7.
Operating Procedures
"+" Post
Ins.Cap
Hold-Down
Clamp
"-" Post
Summary of Contents for DGW500DM
Page 2: ......
Page 42: ... 39 14 Engine Wiring Diagram ...
Page 43: ... 40 15 Generator Wiring Diagram ...
Page 44: ... 2014 ...