Universal Transaction Gateway
Using Legacy External Devices
© 2019 Shift4 Payments, LLC. All rights reserved.
Version 1.4
External Use NDA
Page 9 of 64
Verifying Device Settings
Device settings are nested several levels beneath the SSA System menu. To verify and set device
parameters, complete the following steps:
24. From the SSA System menu, select the
Extended
menu.
25. From the Extended menu, select the
Supervisor
menu. This menu is password protected. Contact
the Shift4 Customer Support team at 702.597.2480, option 2 for the default password.
26. To open and set the Supervisor menu options, enter the password and complete the following steps:
•
Select
Sys Parameters
•
Select
Setup Port
•
Select
Port 1
•
Set or verify port settings as listed in the following table:
Ingenico 6780 Configuration Settings
Setting
Action Required
Value
Interface Type
Set
RS232
Baud Rate
Set
19200
Data Bits
Set
8
Stop Bits
Set
1
Parity
Set
None
LAN Address
Verify
101
Retry Count
Verify
3
Response TMO
Verify
1000
Poll TMO
Verify
3000
Turnaround TMO
Verify
300
27. Press the
Cancel