Other Settings
Verify that the following settings have been applied on the UTG Stub IP to Serial window:
•
Data Bits (Byte Size): 7
•
Parity: Even
•
Stop Bits: 1
•
Flow Control: None
Configuring the Verifone PINpad 1000 Series
The UTG supports two devices in the Verifone PINpad 1000 series, as shown below. The Verifone
®
PINpad 1000 (shown on the left) has 10 number buttons, a red Clear button, and blue Enter button. The
Verifone
®
PINpad 1000se (shown on the right) also has 10 number buttons, in addition to three blue
function keys, a red
“
X
”
(cancel) button, a green arrow (enter) button, and a yellow arrow (clear) button.
Verifone PINpad 1000
Verifone PINpad 1000se
Resetting the Device
To reset the Verifone PINpad 1000 or Verifone PINpad 1000se, complete the following steps:
102.
Disconnect and reconnect the power cord.
103.
While holding down the
CLEAR
or
X
button, press
2
.
104.
When prompted for the password, type
844747746
.
105.
Press
ENTER
.
Setting the Baud Rate
106.
On the scrolling message, watch for the number to press to open the Baud Rate menu.
107.
Press the appropriate number for the Baud Rate menu.