www.enc.net.cn/en
Tel/Fax:86-755-26984485/26985120
3 Function parameter schedule graph
20
FF –password and manufacturer function parameter group
Function
code
name
Set range
unit
Factory
default
modifi
cation
FF.00
User password
0000
-
9999 1
0000
×
FF.01
Manufacturer password
0000
-
9999 1
0000
×
FF.02
FF.0X
Manufacturer’s special parameter
C –supervision function parameter group
Function
code
name
Set range
unit
Factory
default
modifi
cation
C-00
Set frequency
Current set frequency
0.01HZ
C-01
Output freq.
Current output freq.
0.01HZ *
C-02
Output current
Virtual value of current output current
0.1A *
C-03
Output voltage
Virtual value of current output voltage
1V *
C-04
DC bus-bar voltage
Current DC bus-bar voltage
1V *
C-05
Load motor speed
Product of output frequency and load motor
speed emendation factor
1(r/m) *
C-06
Module temperature
IGBT heat sink temperature
1
℃
*
C-07
Run time
Inverter electrification run time
1h *
C-08
accumulative run time Inverter accumulative run time
1h *
C-09
Input terminal status
Switch value input terminal status
――
*
C-10
output terminal status Switch value output terminal status
――
*
C-11
Analog input VCI
Analog input value of VCI
V *
C-12
Analog input YCI
Analog input value of YCI
V *
C-13
Reserved
C-14
Reversed
Summary of Contents for EDS780 Series