3 Function parameter schedule graph
15
F4 –simple PLC function parameter group
Function
code
name
Set range
unit
Factory
default
modifi
cation
F4.00 Simple PLC
running setting
LED first bit:
0: no action
1: stop after single circulation
2: keep final value after single circulation
3: consecutive circulation
LED second bit:
0: start again from first section
1: continue to run at mid-section frequency
LED third bit: PLC run time unit
0: second
1: minute
1 000
×
F4.01 Section 1 setting
000
-
621
LED first bit: frequency setting
0: multi-section freq. i (i=1~7)
1: freq. determined by F0.00 function code
LED second bit: run direction selection
0: forward run
1: reverse run
2: determined by run command
LED third bit: Acc/Dec time selection
0: Acce/Dece time 1
1: Acce/Dece time 2
2: Acce/Dece time 3
3: Acce/Dece time 4
4: Acce/Dece time 5
5: Acce/Dece time 6
6: Acce/Dece time 7
1 000
○
F4.02 Section 1 run time 0
-
6000.0
0.1 10.0
○
F4.03 Section 2 setting
000
-
621
1 000
○
F4.04 Section 2 run time 0
-
6000.0
0.1 10.0
○
F4.05 Section 3 setting
000
-
621
1 000
○
F4.06 Section 3 run time 0
-
6000.0
0.1 10.0
○
F4.07 Section 4 setting
000
-
621
1 000
○
F4.08 Section 4 run time 0
-
6000.0
0.1 10.0
○
F4.09 Section 5 setting
000
-
621
1 000
○
F4.10 Section 5 run time 0
-
6000.0
0.1 10.0
○
F4.11 Section 6 setting
000
-
621
1 000
○
F4.12 Section 6 run time 0
-
6000.0
0.1 10.0
○
F4.13 Section 7 setting
000
-
621
1 000
○
F4.14 Section 7 run time 0
-
6000.0
0.1 10.0
○
Summary of Contents for EDS780 Series