3 Function parameter schedule graph
14
F3.12 Deviation margin
0.0
-
20.0
(%)
percentage relative to 10.00V
0.1(%) 2.0
(
%
)
○
F3.13 Integral separation PID
adjusting threshold
0.0
-
100.0%
0.1(%) 100.0(%)
○
F3.14 Closed-lop preset
frequency
0
-
upper limit frequency
0.01Hz 0.00Hz
○
F3.15 Closed-loop preset
frequency holding
time
0.0-6000s
0.1s 0.0s
○
F3.16
~
F3.26
Reserved
F3.27 Closed-loop adjusting
characteristic
0: Forward function
1: Reverse function
1 0
○
F3.28 LED initial
supervision parameter
selection
0: set frequency
1: output frequency
2: output current
3: output voltage
4: DC bus bar voltage
5: motor speed
6: heat sink temperature
7: run time
8: accumulative run time
9: input terminal status
10: output terminal status
11: analog input VCI/PID provision
1 1
○
F3.29
Zero freq. braking freq.
at starting
0.00Hz-15.00Hz
0.01Hz 0.00
Hz
○
F3.30 Failure relay TA, TC
function selection
0: inverter running
(
RUN
)
1: frequency arriving signal
(
FAR
)
2: frequency level detect signal (FDT1)
3: reserved
4: overload warning alarm signal (OL)
5: output frequency reach high limit
(
FHL
)
6: output frequency reach low limit
(
FLL
)
7: inverter under voltage blockage stop (LU)
8: external failure stop-running
(
EXT
)
9: inverter zero speed running
10: PLC running
11: simple PLC section running finished
12: PLC finish a cycle running
13: reserved
14: inverter ready to run (RDY)
15: inverter failure
16: traverse high and low limit restriction
17: interior counter reach final value
18: interior counter reach specified value
19: set run time arriving
20: interior timing arriving
21~24: reserved
15
○
F3.31 VCI analog input gain
0-800%
100
○