3 Function parameter schedule graph
10
F0.06 S curve rise time 10.0
(%)-
70.0
(%)
(
Acce/Dece time
)
F0.05+F0.06
≤
90
(%)
0.1(
%
) 60.0(%)
○
F0.07 accelerating
decelerating time
unit
0: second
1: minute
1 0
×
F0.08 Acce time 1
0.1
-
6000.0
0.1 20.0
○
F0.09 Dece time 1
0.1
-
6000.0
0.1 20.0
○
F0.10 Upper limit freq. Lower limit freq.
-
400.00Hz
0.01Hz 50.00Hz
×
F0.11 Lower limit freq. 0.00
-
Upper limit freq.
0.01Hz 0.00Hz
×
F0.12 Lower limit freq.
run mode
0: run at lower limit freq.
1: stop running
1 0
×
F0.13 Torque boost
mode
0: manual boost
1: automatic boost
1 0
○
F0.14 Torque boost
0.0
-
20.0
(%)
0.1(%) 4.0(%)
○
F0.15 V/F curve setting 0: constant torque curve
1: degressive torque curve 1
(
the 2.0nd power
)
2: degressive torque curve 2
(
the 1.7th power
)
3: degressive torque curve 3
(
the 1.2th power
)
1 0
×
F0.16 reserved
1 0
×
F1 –start-up, stop, brake function parameter group
Function
code
name
Set range
unit
Factory
default
Modificat-
ion
F1.00 Start-up run mode
0: start at start-up freq.
1: first brake, then start at start-up freq.
2: reserved
1 0
×
F1.01 Start-up freq.
0.0
-
10.00Hz
0.01Hz 0.00Hz
○
F1.02 Start-up freq. duration
0.0
-
20.0S
0.1s 0.0s
○
F1.03 Zero freq. DC braking volt. 0
-
15
(%)
1 0
○
F1.04 Zero freq. DC braking time 0.0
-
20.0S
0.1s 0.0s
○
F1.05 Stop mode
0: Dec stop
1: free stop
2: Dec
+
DC brake stop
1 0
×
F1.06
DC brake initiative freq.
when stop running
0.0
-
15.00Hz
0.01Hz 0.00Hz
○
F1.07
DC brake time when stop
running
0.0
-
20.0s
0.1s 0.0s
○
F1.08
DC brake voltage when stop
running
0
-
15
(%)
1 0
○
F2 –auxiliary run function parameter group
Function
name
Set range
unit
Factory
modif-