UP-3301US
OPTIONS
– 8 –
4. Service tools
5. Supplies : None
6. How to use the service tools
6-1. Expansion PWB : CKOG-6724BHZZ
• Extrenal view
• Plain view
• Connection diagram
6-2. MCR test card: UKOG-6718RCZZ
• Used when executing the diagnostics for the UP-E12MR2.
• External view
No.
NAME
PARTS CODE
PRICE
DESCRIPTION
1
MCR test card
UKOG-6718RCZZ
BE
for UP-E12MR2
2
RS232 loop back connector
UKOG-6705RCZZ
BC
for RS232 connector
3
Expansion PWB
CKOG-6724BHZZ
BX
for ER-A7RS2
Test pins : Used to check the bus signals.
Bus connector : Used to check the bus signals.
Connected to the UP-3301 Mother PWB.
UP-3301 bus connector
ER-A7RS2
Summary of Contents for UP-3301
Page 91: ...UP 3301US PWB LAYOUT 89 CHAPTER 9 PWB LAYOUT 1 MAIN PWB A side ...
Page 92: ...UP 3301US PWB LAYOUT 90 B side 8 CUSTOMER DISPLAY PWB ...
Page 93: ...UP 3301US PWB LAYOUT 91 2 IR PWB 3 LCD PWB A Side B Side 4 INVERTER PWB A Side B Side ...
Page 94: ...UP 3301US PWB LAYOUT 92 5 MOTHER PWB 6 N F PWB 7 TOUCH PANEL PWB ...
Page 95: ...UP 3301US PWB LAYOUT 93 ...
Page 111: ......