MX-M260/M310/M260N/M310N SIMULATION 6 - 24
Operation/procedure
Set the OC cover at 20 degrees detection and press the [START] key.
The detection output level of each sensor is displayed in real time.
The value in [ ] shows the threshold value of 20 degree detection
adjustment. (Hexadecimal display)
For AB series, 1 to 5 is displayed, for inch series, 1 to 4.
During execution, [EXECUTING] is highlighted.
Operation/procedure
1.
Touch the item to be set.
2.
Enter the set value with the 10-key.
Operation/procedure
Input the set value with the 10-key and press the [START] key.
OCSW
Original cover state
Open: Highlighted display
Close: Normal display
1 to 5
PD sensor detection level (Hexadecimal display)
43
43-1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature.
Section
Fixing (Fusing)
Item
Operation
Item
Content
Setting
range
Default
(North
America
/Others)
(Europe)
1
Ready
Temp Main
(145)
Ready
temperature Main
(145mm/s)
150 -
220
185
190
2
Ready
Temp Sub
(145)
Ready
temperature Sub
(145mm/s)
150 -
220
180
185
3
Ready
Temp Main
(122)
Ready
temperature Main
(122mm/s)
150 -
220
175
180
4
Ready
Temp Sub
(122)
Ready
temperature Sub
(122mm/s)
150 -
220
170
175
5
WarmUp
Target Main
(145)
Warmup target
temperature Main
(145mm/s)
150 -
220
180
190
6
WarmUp
Target Sub
(145)
Warmup target
temperature Sub
(145mm/s)
150 -
220
180
190
7
WarmUp
Target Main
(122)
Warmup target
temperature Main
(122mm/s)
150 -
220
175
8
WarmUp
Target Sub
(122)
Warmup target
temperature Sub
(122mm/s)
150 -
220
170
9
WarmUp
Temp Main
(145)
Warmup
complete
temperature Main
(145mm/s)
0 - 40
10
10
WarmUp
Temp Sub
(145)
Warmup
complete
temperature Sub
(145mm/s)
0 - 40
15
11
WarmUp
Temp Main
(122)
Warmup
complete
temperature Main
(122mm/s)
0 - 40
10
12
WarmUp
Temp Sub
(122)
Warmup
complete
temperature Sub
(122mm/s)
0 - 40
15
13
600dpi
Main (145)
600dpi Main
(145mm/s)
150 -
220
190
195
14
600dpi Sub
(145)
600dpi Sub
(145mm/s)
150 -
220
190
195
15
POST
CARD
Main (145)
Postcard Main
(145mm/s)
150 -
220
200
16
POST
CARD Sub
(145)
Postcard Sub
(145mm/s)
150 -
220
200
17
CARDBOA
RD Main
(145)
Thick paper Main
(145mm/s)
150 -
220
200
18
CARDBOA
RD Sub
(145)
Thick paper Sub
(145mm/s)
150 -
220
200
19
600dpi
Main (122)
600dpi Main
(122mm/s)
150 -
220
175
185
20
600dpi Sub
(122)
600dpi Sub
(122mm/s)
150 -
220
175
185
21
CARDBOA
RD Main
(122)
Postcard Main
(122mm/s)
150 -
220
190
22
POST
CARD Sub
(122)
Postcard Sub
(122mm/s)
150 -
220
190
23
POST
CARD
(122mm/s)
Thick paper Main
(122mm/s)
150 -
220
190
24
CARDBOA
RD Sub
(122)
Thick paper Sub
(122mm/s)
150 -
220
190
43-10
Purpose
Setting
Function
(Purpose)
Used to set the paper feed cycle timing when printing
postcards.
Section
Paper feed
Item
Operation
Setting range
1-99
Default
50
44
44-1
Purpose
Setting
Function
(Purpose)
Used to make various setups in each mode of process
control.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Item
Content
Setting
range
Default
(North
America
/Others)
(Europe)