MX-M260/M310/M260N/M310N SIMULATION 6 - 11
Output is made with the entered value for 30sec, and the display
returns to the original state.
The minimum increment is 10V.
The result of (Set value) -200/ 10 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value
*10+200) is used as the set value.
Operation/procedure
1.
Touch the exposure mode to be changed.
The current set value is highlighted.
2.
Enter the set value with the 10-key.
3.
Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
Min. unit: 10V increment
Operation/procedure
1.
Enter the set value with the 10-key.
2.
Press the [START] key.
Output is made with the entered value for 30sec. and the display
returns to the original state.
The minimum increment is 10V.
The result of (Set value-200) / 10 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value
∗
10
+200) is used as the set value.
Therefore, an even number must be entered. If not, the entered odd
1 is displayed after pressing [START] key.
Operation/procedure
1.
Enter the set value with the 10-key.
2.
Press the [START] key.
Output is made with the entered value for 30sec. and the display
returns to the original state.
Operation/procedure
1.
Select the operation mode with the 10-key.
2.
Press the [START] key.
The operation is performed for 30sec, and the display returns to the
original state.
Item
Content
Installa
tion
range
Default
1
DENS1 (145)
Density1 (145mm/s)
200-
650
300
2
DENS2 (145)
Density2 (145mm/s)
370
3
DENS3 (145)
Density3 (145mm/s)
420
4
DENS4 (145)
Density4 (145mm/s)
530
5
DENS5 (145)
Density5 (145mm/s)
600
6
TS (145)
Toner save (145mm/s)
250
7
DENS1 (122)
Density1 (122mm/s)
300
8
DENS2 (122)
Density2 (122mm/s)
370
9
DENS3 (122)
Density3 (122mm/s)
420
10 DENS4 (122)
Density4 (122mm/s)
530
11 DENS5 (122)
Density5 (122mm/s)
600
12 TS (122)
Toner save (122mm/s)
250
8-11
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage in each printer mode and the
control circuit.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Item
Content
Installa
tion
range
Default
1
DENS1 (145)
Density 1 (145mm/s)
350-
750
440
2
DENS2 (145)
Density 2 (145mm/s)
510
3
DENS3 (145)
Density 3 (145mm/s)
560
4
DENS4 (145)
Density 4 (145mm/s)
670
5
DENS5 (145)
Density 5 (145mm/s)
740
6
TS (145)
Toner save (145mm/s)
390
7
DENS1 (122)
Density 1 (122mm/s)
440
8
DENS2 (122)
Density 2 (122mm/s)
510
9
DENS3 (122)
Density 3 (122mm/s)
560
10 DENS4 (122)
Density 4 (122mm/s)
670
11 DENS5 (122)
Density 5 (122mm/s)
740
12 TS (122)
Toner save (122mm/s)
390
8-13
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in FAX mode and the control
circuit.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner hopper
Setting range
200-650
Default
450
8-14
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage in FAX mode and the control
circuit.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Setting range
350-750
Default
590
9
9-1
Purpose
Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the load
(motor) in the duplex section and the control circuit.
Section
Duplex
Item
Operation
Item
Content
1
DMF145
Duplex motor/Duplex 2 motor forward rotation
(145mm/s)
2
DMF122
Duplex motor/Duplex 2 motor forward rotation
(122mm/s)
3
DMR145
Duplex motor/Duplex 2 motor reverse rotation
(145mm/s)
4
DMR122
Duplex motor/Duplex 2 motor reverse rotation
(122mm/s)