
MX-M260/M310/M260N/M310N SIMULATION 6 - 10
Operation/procedure
1.
Warm-up starts by the cover open/close.
(Can be performed repeatedly by open/close of the cover.)
2.
The warm-up time is counted up and displayed in the unit of sec.
If the [CA] key is pressed at this time, count-up is interrupted to ter-
minate the simulation. (However, warm-up is continued.)
3.
After completion of warming up, “WARM UP COMPLETED” is dis-
played and the control returns to the initial screen.
Operation/procedure
1.
Touch the exposure mode to be changed.
The current set value is displayed.
2.
Enter the set value with the 10-key.
3.
Press the [START] key.
Output is made with the entered value, and the display returns to the
original state.
(
∗
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
The minimum increment is 10V.
The result of (Set value) -200/ 10 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value
*10+200) is used as the set value.
Operation/procedure
1.
Touch the exposure mode to be changed.
The current set value is displayed.
2.
Enter the set value with the 10-key.
3.
Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
Min. unit: 10V increment
(
∗
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
Operation/procedure
1.
Touch the exposure mode to be changed.
The current set value is displayed.
2.
Enter the set value with the 10-key.
3.
Press the [START] key.
7-8
Purpose
Setting/Operation test/check
Function
(Purpose)
Used to set the display of the warm-up time.
Item
Operation
8
8-1
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in each copy mode and the
control circuit.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner hopper
Item
Content
Setting
range
Default
1
AE (145)
AE (145mm/s)
200-
650
450
2
TEXT (145)
Character (145mm/s)
450
3
TEXT/PHOTO (145)
Character/Photo
(145mm/s)
450
4
PHOTO (145)
Photo (145mm/s)
450
5
TONER SAVE (145)
Toner save (145mm/s)
400
6
AE (122)
AE (122mm/s)
450
7
TEXT (122)
Character (122mm/s)
450
8
TEXT/PHOTO (122)
Character/Photo
(122mm/s)
450
9
PHOTO (122)
Photo (122mm/s)
450
10
TONER SAVE (122)
Toner save (122mm/s)
400
8-2
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage in each copy mode and the control
circuit.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Item
Content
Setting
range
Default
1
AE (145)
AE (145mm/s)
350-
750
590
2
TEXT (145)
Character (145mm/s)
590
3
TEXT/PHOTO (145)
Character/Photo
(145mm/s)
590
4
PHOTO (145)
Photo (145mm/s)
590
5
TONER SAVE (145)
Toner save (145mm/s)
540
6
AE (122)
AE (122mm/s)
590
7
TEXT (122)
Character (122mm/s)
590
8
TEXT/PHOTO (122)
Character/Photo
(122mm/s)
590
9
PHOTO (122)
Photo (122mm/s)
590
10
TONER SAVE (122)
Toner save (122mm/s)
540
8-10
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in each printer mode and the
control circuit.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner hopper