MX-M260/M310/M260N/M310N SIMULATION 6 - 4
26
1
Used to set whether the job separator is installed
or not. (Since this cannot be detected by hardware
detection, it is set in this simulation.)
2
Used to set whether the automatic detection of
paper size is made or not.
3
Used to set the specifications of the auditor.
Setting must be made depending on the use
condition of the auditor.
5
Used to set the count mode of the total counter and
the maintenance counter.
6
Used to set the specifications depending on the
destination.
10
Network scanner trial mode setting
12
Used to input the Software Key for E-MAIL RIC.
14
Used to input the Software Key for the PS
extension kit.
18
Used to set enable/disable of toner save operation.
22
Used to set the specification (language display) for
the destination.
30
Used to set ON/OFF of the heater lamp slow-up
control conforming to the CE mark control.
35
Used to set whether the same continuous troubles
are displayed as one trouble or the series of
troubles with SIM 22-4 when the same troubles
occur continuously.
36
Used to set whether the machine is stopped or not
when the maintenance counter life is expired.
50
Used to set ON/OFF of the black and white
reversion function.
56
Gamma life correction setting
57
Used to set the model code.
60
Used to set enable/disable of the FAX mode key
when FAX is not installed. (When FAX is installed,
the FAX mode is enabled regardless of this setup.)
69
Toner near end setting
71
In the power save time setting, the pre-heat (pre-
heat mode setting) and the auto power shut off
time can be set to the short time setup (pre-heat: 1
min, auto power shut off: 4 min) and the long time
setup (pre-heat: 15min, auto power shut off:
60min).
72
The letterhead support is set.
When “Letterhead paper setting” is selected, the
set value of SIM 26-46 (Image output direction
setting) is set to “Setting Enable” accordingly.
27
1
Used to set PC/MODEM communication trouble
(U7-00) detection Yes/No.
2
Sender’s registration number/HOST server TEL
number.
4
Function setting
5
Used to set the tag number
7
FSS function setting
9
FSS function adjustment
10
Trouble precognition history clear
14
FSS connection test setting
15
Displays status of FSS connection
30
1
Used to display the sensor status attached to the
machine.
2
Used to display the status of the sensors attached
to the standard tray and the manual feed tray. (Use
SIM 4-2 for the option trays.)
The sensor of an uninstalled tray is not displayed.
Code
Function
Main
Sub
40
1
Used to check the sensor of the machine manual
feed tray.
2
Used to adjust the manual paper feed tray paper
width detector detection level.
3
The AD conversion value of manual feed width
detection is displayed.
41
1
Used to check the document size detection photo
sensor.
2
Used to adjust the detection level of the document
size photo sensor.
3
Used to check the light reception level and the
detection level of the original size detection photo
sensor.
4
Used to adjust the detection level of OC 20
degrees.
43
1
Used to set the fusing temperature.
10
Used to set the paper feed cycle timing when
printing postcards.
44
1
Used to make various setups in each mode of
process control.
2
Drum life correction setting
3
Used to set the DV count correction.
9
Used to display the process control correction
information.
14
Used to display the environment (temperature,
humidity) correction information.
16
Used to set the toner density control correction
value.
17
Used to display the toner density control reference
value.
34
Used to set the transfer current value in each
mode.
40
Used to set the time from the start of the main
motor rotation (Ready) to the start of toner supply
in previous rotation after turning on the power.
46
2
Used to set the exposure level in each exposure
mode.
9
Used to adjust the shift amount and the inclination
value for each level (1 to 5) of the exposure mode
(Text).
10
Used to adjust the shift amount and the inclination
value for each level (1 to 5) of the exposure mode
(Text/Photo).
11
Used to adjust the shift amount and the inclination
value for each level (1 to 5) of the exposure mode
(Photo).
12
FAX exposure level adjustment
(1 mode automatic adjustment)
13
FAX exposure level adjustment
(Normal mode individual adjustment)
14
FAX exposure level adjustment
(Fine text mode individual adjustment)
15
FAX exposure level adjustment
(Super Fine mode individual adjustment)
16
FAX exposure level adjustment
(Ultra Fine mode individual adjustment)
18
Used to adjust inclination for each exposure mode.
19
Used to set the control method of the exposure
mode.
20
Used to set the exposure correction value of SPF/
RSPF for OC exposure.
30
Used to set the AE and the limit value in AE
(Toner save).
31
Used to set the AE and the limit value in AE
(Toner save).
39
Used to switch the FAX send image quality.
Code
Function
Main