Maintenance
16
SHARP
Document Solution Centre
Interval Checklist
500k
1000k
3000k Process Section:
x
Replace Developer [MX-900GV]
x
Replace OPC Drum [MX-850GR]
Replace Developer Maintenance Kit [MX-900DK]:-
•
Doctor cover unit / DV seal.
•
DV side seal F.
•
DV side seal R.
•
DV box filter.
•
DV toner filter.
Replace Cleaning Blade Kit [MX-900CB]:-
•
Cleaning blade.
•
Side seal F.
•
Side seal R.
•
Sub blade.
•
Drum separation pawl x4
•
Duct sheet.
Relocate Drum Separation Pawl mounting position
Clean Before-Transfer Discharge Lamp.
Clean OPC Drum Surface Potential Sensor
Use Blow Brush or Dry Cloth – DO NOT CLEAN with Vacuum Cleaner
Replace Main Charge Kit [MX-900MK]:-
•
Charger wire x2.
•
Screen grid.
•
Charger cleaner.
•
Charger cushion.
•
Cleaner base guide.
x
Clean Main Charger Case
x
x
Replace Main Charger Case
[PCASZ0326FCZ1]
x
x
Replace Process Unit Blade Side Seal Front
[PSEL-0992FCZ1]
and
Rear
[PSEL-0991FCZ1]
Replace Ozone Filter Kit [MX-900FL] :-
•
Ozone filter
•
Outlet filter.
x
Sim 24-05
Clear Developer Print, Rotation & Day Counter
(only when Developer is replaced)
x
Sim 25-02
Toner Concentration Adjustment
(only when Developer is replaced)
Sim 24-04
Clear MAINTENANCE ALL Counter
x
Sim 24-04
Clear DRUM CRTG K Counter
(only when OPC Drum is replaced)
Sim 24-04
Clear DRUM BLADE K Counter
(only when Drum Cleaner Blade is replaced)