1-23
Setting and Operating Outline
1
Item
Specifications
IV-S30J
Number of measurement
programs
Maximum 6 per object type (measurement 0 - camera 1, measurement 0 -
camera 2, measurements 1 to 4)
Note: Measurement 0 is only used for positional deviation measurement.
Window shape
Rectangle, circle, oval (when using area measurement by binary
conversion, object counting by binary conversion, object identification by
binary measurement), polygon window (maximum 32 sided polygons: When
binary area measurement, counting after binary conversion, or object
identification (labeling) after binary conversion is selected.)
Distance and angle
measurement
Measure distance (between two points, X coordinate, Y coordinate),
measure angle (3 points, 2 points against horizontal line, 2 points against
vertical line), auxiliary point (center, circle center, gravity center, line over 2
points, crossing point of two straight lines)
Arithmetic operation
Four basic operations (+, -, X, /), root, absolute value, TAN, ATAN,
maximum, minimum, average , total.
Other functions
Display measuring time, light level monitor function, crosshair cursor
display, change display language between Japanese and English, Run
screen lock function, setting menu display "yes/no", change image display
(through/freeze), change image brightness (bright/dark)
Input relays
Parallel input: 7 points (X0 to X6)
Output relays
Parallel output: 8 points (Y0 to Y7)
General-purpose serial interface, computer link: 16 points (Y0 to Y15)
Auxiliary relays
128 points (C0 to C127), special area 18 points (C110 to C127)
Timers
8 points (TM0 to TM7), timer setting range: 0.01 to 9.99 seconds
(countdown timer)
Counters
8 points (CN0 to CN7), counter setting range: 001 to 999 (counts down)
Parallel interface
Input: 7 points, 12/24 VDC
Output: 9 points, 12/24 VDC
General-purpose
serial interface
RS232C/RS422 (2.4 to 115.2 kbps)
Computer link
Built-in compatibility with certain SHARP, OMRON, and Mitsubishi models
Image output
1 channel, EIA 525 lines, 2:1 interlace
Number of cameras
Maximum of 2
Make settings
Using the IV-S30RK1 remote keypad and/or the IV-S30SP parameter
setting support software
Measu-
rement
start
input
Internal trigger
CCD trigger (using the CCD camera)
External trigger
Trigger input (parallel I/F), general-purpose serial I/F, keypad trigger (for
manual measuring)
Interrupt processing
input
1 point: External trigger (X0)
Inputs
4 points: Object type change (X1 to X4)
2 points: External input (X5, X6)
Common for input
1 point: + common
Output
9 points: 1 READY , 8 user settable logical outputs (Y0 to Y7)
Common for output
1 point: + common
Power supply
2 points: +24 VDC, 0 V
Power voltage/consumption
24 VDC (±10 %) 7 W
Micro PC section
External
interface
Terminal block