SPECIFICATIONS
FOR A COMPLETE DESCRIPTION OF THE OPERATION OF THIS UNIT, PLEASE REFER
TO THE OPERATION MANUAL.
IMPORTANT SERVICE NOTES (FOR U.K. ONLY)
Before returning the unit to the customer after completion of a
repair or adjustment it is necessary for the following withstand
voltage test to be applied to ensure the unit is safe for the
customer to use.
Setting of Withstanding Voltage Tester and set.
Set name
set value
Withstanding Voltage Tester
Test voltage
2,120 VPEAK
1,500 VRMS
Set time
60 secs
Set current (Cutoff current)
4 mA
Unit
Judgment
OK: The “GOOD” lamp lights.
NG: The “NG” lamp lights and the buzzer sounds.
SHORT-CIRCUIT
AC POWER
SUPPLY CORD
CONNECT THE PROBE
TO GND
OF CHASSIS
SCREW
PROBE
AC
UNIT
WITHSTANDING
VOLTAGE TESTER
+
-
OUT
Channel:
Stereo 2 channels
Frequency range: 2 Hz - 100 kHz
(Super Audio CD)
Frequency
2 Hz - 50 kHz
response:
(Super Audio CD)
2 Hz - 20 kHz
(CD)
Total harmonic
distortion:
0.0012 % (1 kHz, 2 V)
Dynamic range:
105 dB or more
(Super Audio CD)
Wow and flutter:
Unmeasurable (less than
±
0.001 % W. peak)
Output terminals:
1-bit digital output terminal
x 1
RCA coaxial digital output
x 1
Square type optical digital
output x 1
RCA analog output
(FIXED) x 1
RCA analog output (VARI-
ABLE) x 1
Headphone jack [3.5 mm
(1/8”)] x 1
Other terminals:
AC input x 1
Power source:
Power
consumption:
Dimensions:
Width; 300 mm (11 - 13/16”)
Height; 66 mm (2 - 5/8”)
Depth; 382 mm (15 - 1/16”)
Weight:
Approx. 5.8 kg (12.79 lbs.)
230 V, 50 Hz
16 W