AR-M207 M165 M162 SIMULATIONS 7-18
24
13
Scanner counter clear
Used to clear the scanner counter.
[OK] or [START] key: Clears the scanner counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
14
SPF jam total counter clear
Used to clear the SPF jam total counter.
[OK] or [START] key: Clears the SPF jam total counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
15
Scanner mode counter clear
Used to clear the scanner mode counter.
[OK] or [START] key: Clears the scanner mode counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
25
01
Main motor operation check (Cooling fan motor rotation check)
When [OK] key or [START] key is pressed, the main motor (as well as the duplex motor in the case of the
duplex model) is rotated for 30 sec.
If the developing unit is installed to save toner consumption at that time, the developing bias, the main
charger, and the grid are also outputted.
In addition, since laser discharge is required when the motor is stopped, the polygon motor is also operated.
Check if the developing unit is installed or not. If it is not installed, the previous high voltage is not outputted
and only the motor is rotated.
After completion of 30sec operation, the machine shifts to the sub code input window.
* This simulation must not be executed with the door open/close switch forcibly turned ON.
After completion of the process, the machine shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts the output operation, and shifts to the sub code input window.
Main
code
Sub
code
Contents
Remark
Sim24-13 COUNTER CLR
AER YOU SURE? EXEC
SCAN COUNTER
CLEAR
Sim24-14 COUNTER CLR
AER YOU SURE? EXEC
SPF JAM COUNTER
CLEAR
Sim24-15 COUNTER CLR
AER YOU SURE? EXEC
SCANNER MODE
COUNTER CLEAR
Sim25-1 MAIN MOTOR
PRESS OK KEY
EXEC
Sim25-1 MAIN MOTOR
EXEC
OK/START Key
(Execution start window)
(Execution window)
[07]SIMULATIONS.fm 18
ページ
2004年11月17日 水曜日 午後12時11分