AR-M207 M165 M162 SIMULATIONS 7-4
02
01
Single Paper Feeder(SPF)aging
Used to check the operations of the SPF unit and its control circuit.
Enter the magnification ratio and press OK or [START] key to drive the SPF unit at the speed corresponding
to the setting.
* When [Interruption] key is press, the simulation is terminated and the machine returns to the sub code
input window.
* When [CA] key is pressed, the simulation is terminated and the machine exits the simulation mode.
02
SPF sensor status display
Used to display the sensor status in the SPF/RSPF section. An active sensor is highlighted.
[CA] key: Exits the simulation mode.
[Interruption] key: Returns to the sub code input window.
03
SPF motor operation check
Used to check the operation of the SPF motor and its control circuit. When this simulation is executed, the
initial menu shown below is displayed. Select the magnification ratio to drive the motor.
[CA] key: The SPF motor is stopped, and the machine exits the simulation mode. [Interruption] key: The SPF
motor is stopped, and the machine returns to the sub code input window.
Main
code
Sub
code
Contents
Remark
Sim2-1 SPF AGING
115%
100%
86%
1SIDE
2SIDE
OK/START Key
(Magnification ratio selection window)
ZOOM
100%
EXEC
Sim2-1 SPF AGING
115%
100%
86%
1SIDE
2SIDE
(Execution
window)
ZOOM
100%
EXEC
Select the scan magnification ratio (drive speed).
This also accords with the magnification ratio and
the speed in copying similarly to the OC.
The setting range is 50% - 200%.
"EXEC" is highlighted during execution.
Sim2-2 SENSOR CHECK
SPFP
OCCV
POUT
SPFC
L1
L2
W0
W1
W2
W3
Displayed name
: Sensor name
SPFP
:SPF document transportation sensor
OCCV
:SPF unit (OC cover) open/close sensor
POUT
:SPF paper exit sensor
SPFC
:SPF paper feed cover open/close sensor
L1
:SPF paper length sensor 1
L2
:SPF paper length sensor 2
W0
:SPF document set sensor
W1
:SPF paper width sensor (small)
W2
:SPF paper width sensor (middle)
W3
:SPF paper width sensor (large)
Sim2-3 OUTPUT CHECK
Sim2-3 OUTPUT CHECK
115%
100%
86%
OK/START Key
(Initial window = Magnification ratio selection window)
ZOOM
100%
EXEC
115%
100%
86%
ZOOM
100%
EXEC
(Execution
window)
Select the scan magnification ratio (drive speed).
This also accords with the magnification ratio and
the speed in copying.
The setting range is 50% - 200%.
"EXEC" is highlighted during execution.
[07]SIMULATIONS.fm 4
ページ
2004年11月17日 水曜日 午後12時11分