AR-FX7 SOFT SWITCH 7 - 6
∗
: UK = U.K.,
G = Germany,
F = France
SW
No.
Data
No.
Items
SW selection and functions
Default value
∗
Remarks
UK G
F
S
W
19
1
Minimum pause time
(10PPS) setup
Binary
input
Bit No.
Setting range
1
2
3
4
0 (525ms) to 15 (900ms)
X (ms) = (N × 25) + 525
825ms
1
1
1
2
1
1
1
3
0
0
0
4
0
0
0
5
Inhibited to use
0
0
0
6
0
0
0
7
0
0
0
8
0
0
0
S
W
20
1
Inhibited to use
0
0
0
2
PBX setup
(Inhibited except for
Germany and France.)
Bit No.
2
3
4
Setup OFF
0
0
0
When the value is
outside the
setting range, the
initial value is set.
3
Setup OFF
0
0
0
0
0
0
4
Flash send
1
0
1
0
0
0
ID send
1
1
0
5
SIM DTMF sound
speaker selection
window
1: Yes
0: No
No
0
0
0
6
Flash send wait time
Bit No.
6
7
0sec
(U.K., France)
1sec (Germany)
0
1
0
Fixed to 0 except
for Germany.
0sec
0
0
0.5sec
0
1
7
1sec
1
0
0
0
0
2sec
1
1
8
Receivable memory
capacity
1: 64Kbyte
0: 128Kbyte
128Kbyte
0
0
0
S
W
21
1
Dial tone detection
1: Yes
0: No
No
0
0
0
2
Busy tone detection
1: Yes
0: No
Yes
1
1
1
3
Dial tone monitoring
time
1: 10sec
0: 5sec
5sec
0
0
0
4
CED detection time
1: 500ms
0: 1000ms
1000ms
0
0
0
5
Inhibited to use
0
0
0
6
0
0
0
7
0
0
0
8
0
0
0
S
W
22
1
Waiting time for dial
start
Bit No.
1
2
3.5sec
0
0
0
3.5sec
0
0
4sec
0
1
2
5sec
1
0
0
0
0
6sec
1
1
3
CNG send start time
Bit No.
3
4
0.5sec
0
0
0
0.5sec
0
0
4
1.0sec
0
1
0
0
0
1.5sec
1
0
5
Tone/pulse default
setup
Bit No.
5
6
TONE
1
1
1
10PPS
0
0
6
20PPS
0
1
0
0
0
TONE
1
0
7
DPMUTE control
1: ON
0: OFF
OFF
0
0
0
8
DP dial pulse number
process
1: 10-N
0: Normal (N)
Normal (N)
0
0
0
S
W
23
1
Inhibited to use
0
0
0
2
Monitoring polarity
reversion during send
image
1: Yes
0: No
No
0
0
0
Fixed to No.
3
Monitoring polarity
reversion during
communication
1: Yes
0: No
No
0
0
0
Fixed to No.
4
Setting of time before
dial (10PPS)
Binary
input
Bit No.
Setting range
4
5
6
7
8
0 (50ms) to 31 (360ms)
X (ms) = (N × 10) + 50
300ms
1
1
1
5
1
1
1
6
0
0
0
7
0
0
0
8
1
1
1