AR-FX7 SIMULATION 6 - 12
Operation/Procedure
Signal detection is checked and the result is displayed.
Note: Executable only when the FAX is installed.
Operation/procedure
The send/receive test is performed, and the time required for send/
receive of the image data in the test is measured and displayed.
When there are two or more send/receive operations of image data in
one communication, only the time of the last send/receive data near
the end is measured.
Note: Executable only when the FAX is installed.
Operation/procedure
The following test sound is delivered to the line and the speaker to
adjust the sound kind and volume.
The send level to the line is the set value of soft SW.
The set values of the selected sound kind and volume are written to
each soft SW.
1.
Sound kinds pattern
LAR: (MED. Value + 1)
MED: (SMA value +1) - (LAR value - 1)
SMA: 1 - (MED. Value + 1)
2.
Sound volume pattern
Note: Executable only when the FAX is installed.
Operation/procedure
When the [START] key is pressed, the call signal from CI pin is
detected to deliver the call sound to the line and the speaker. The vol-
ume of call sound follows the soft SW.
Signal detection and delivery of pseudo-call sound at detection are
executed until the interruption command is provided by pressing the
[CUSTOM SETTINGS] key.
Note: Executable only when the FAX is installed.
Operation/procedure
When the [START] key is pressed, the machine ringer and the pseudo-
ringer would ring.
By pressing [CUSTOM SETTINGS] key, the operation can be can-
celed.
66-33
Purpose
Operation test/check
Function (Purpose)
Signal detection check
Section
FAX
Item
Operation
66-34
Purpose
Operation test/check
Function (Purpose)
Communication time measurement display
Section
FAX
Item
Operation
Setup on the user
side when executing
communication
Communication
means
Picture quality
Density
ECM
Sender information
: Memory send
: Normal Character
: Lighter
: ON
: OFF
Measuring
range
Send
From flag reception before sending of
image data until sending of RCP frame
Receive
From flag reception before reception of
image data until reception of RCP frame
Mode when measuring
Used to make communication not in a
simulation process but in the normal screen
and measure the time.
How to check the time
Enter the simulation for communication time
check and check the time.
Measuring unit
msec
66-37
Purpose
Adjustment/Setting/Check
Function (Purpose)
Speaker sound volume adjustment
Section
FAX
Sound kinds (Test sound)
Sound volume set value
RINGER
Call sound
DEF. LAR. MED. SMA.
LINE MONITO
Line monitor sound (Test
sound: communication
signal sound)
DEF. LAR. MED. SMA.
ON HOOK
On-hook (Test sound,
communication signal
sound)
DEF. LAR. MED. SMA.
SCAN FINISH
Scan finish sound
DEF. LAR. MED. SMA.
TX/RX FINISH
Communication finish
sound
DEF. LAR. MED. SMA.
DTMF
DTMF send sound
DEF. LAR. MED. SMA.
66-41
Purpose
Adjustment/Setting/Check
Function
(Purpose)
CI signal check
66-52
Purpose
Operation test/check
Function
(Purpose)
Ringer check
1