AR-FX7 SOFT SWITCH 7 - 35
SW42 No. 8 V.34 mode function in manual communication
Used to set Enabled/Disabled V.34 mode function in manual communi-
cation.
When set to 1, V.34 mode function is enabled.
When set to 0, V.34 mode function is disabled.
Default: 1 (V.34 mode function is enabled.)
SW43 No. 1 V.34 mode function
Used to set whether V.34 mode is used for send/receive with the other
party machine is provided with V.34 mode.
When set to 1, send/receive is made with using V.34 mode.
When set to 0, send/receive is made without using V.34 mode.
Default: 1 (Send/receive is made using V.34 mode)
SW43 No. 2 Super G3 disabled in the last call-out of recall
in case of an error
Used to set Enable/disable of Super G3 in the last call-out of recall in
case of an error.
Default: 0 (Super G3 is void)
SW43 No. 3 V.34 primary channel return mode
Used to set V.34 primary channel return mode.
Default: 1 (PPh)
SW43 No.4–No.6 Symbol speed mask in V.34 reception
Used to set the symbol speed mask in V.34 reception.
Default: 1 0 1 (3429)
SW43 No. 7 V.34 control channel communication speed
Used to set the communication speed of control channel in V.34 mode
transmission.
When set to 1, the communication speed of control channel is
2400bps.
When set to 0, the communication speed of control channel is
1200bps.
Default: 0 (1200bps)
SW43 No. 8 Control channel retrain judgment in V.34
reception
Used to set the control channel retrain judgment in V.34 reception.
Default: 0 (EQM value judgment)
SW44 No.1–No.4 V.34 primary channel transmission
speed
Used to set the communication start speed in V.34 mode transmission.
Setup is made in the range of 2400 – 33600bps by binary input of N in
"2400 × N".
N can be set in the range of 0 – 15. Setting to 0 comes 2400bps, 15
comes 33600bps.
Default: N=14 (Transmission starts from 33600bps)
SW44 No.5–No.8 V.34 primary channel reception speed
Used to set the reception start speed in V.34 mode.
Setup is made in the range of 2400 – 33600 bps by binary input of N in
"2400 (bps) × N".
N can be set in the range of 0 – 15. Setting to 0 comes 2400bps, 15
comes 33600bps.
Default: N=14 (Reception starts from 33600bps)
SW45 No.1, No.2 Speaker volume at scanner scan end
Used to set the volume of scan end sound from the speaker when scan
is completed.
Default: 1 0 (Medium)
SW45 No.3–No.8 Pattern number of speaker volume at
scan end
Pattern of scan end sound volume (Large/Medium/Small)
Default: 21
SW46 No.1, No.2 Speaker volume in DTMF send
Used to set the volume of transmission sound and DTMF sound from
speaker when pressing on-hook button.
Default: 1 0 (Medium)
SW46 No.3–No.8 Pattern number of speaker volume in
DTMF send
Pattern of volume in DTMF send (Large/Medium/Small)
Default: 21
SW47 No.1, No.2 Volume of line monitor from speaker
Used to set the line sound volume from the speaker in FAX transmis-
sion.
Default: 0 0 (Silent)
SW47 No.3–No.8 Pattern number of line monitor’s volume
Pattern of line monitor volume (Large/Medium/Small)
Default: 21
SW48 No.1, No.2 Volume of communication end sound
Used to set the volume of communication end sound from the speaker
when communication is completed.
Default: 1 0 (Medium)
SW48 No.3–No.8 Pattern number of communication end
sound
Pattern of communication end sound volume (Large/Medium/Small)
Default: 21
SW49 No.1, No.2 On-hook speaker volume
Used to set the volume from the speaker in on-hook.
Default: 1 0 (Medium)
SW49 No.3–No.8 Pattern number of on-hook speaker
volume
Used to set the volume pattern (large/medium/small) in on-hook.
Refer to SIM66-37.
Default: 21
SW50 No.1, No.2 Call sound volume
Used to set the ringing sound volume.
Default: 1 0 (Medium)
SW50 No.3–No.8 Pattern number of ringing speaker
volume
Pattern of call sound volume (Large/Medium/Small)
Default: 21
SW51 No.1, No.2 Busy tone detection cycle
Used to set the number of pulses of busy tone detected to recognize
as busy tone.
When set to 0 0, 2 pulses are detected.
When set to 0 1, 4 pulses are detected.
When set to 1 0, 6 pulses are detected.
When set to 1 1, 10 pulses are detected.
Default: 0 0 (2 pulses are detected)
SW51 No. 3 Busy tone detection time (Upper limit)
Busy tone detection time (Upper limit)
1: 650ms
0: 750ms
Default: 0 (750ms)
SW51 No. 4 Busy tone detection time (Lower limit)
Busy tone detection time (Lower limit)
1: 350ms
0: 250ms
Default: 0 (250ms)
SW51 No. 5 Busy tone detection time (Lower limit 2)
Busy tone detection time lower limit 2
1: 150ms
0: Follows SW51-4.