AR-FX7 SOFT SWITCH 7 - 3
SW
No.
Data
No.
Items
SW selection and functions
Default value
Remarks
S
W
3
1
Sharp machine mode
1: ON
0: OFF
ON
1
2
Sharp machine mode (F
code)
1: ON
0: OFF
OFF
0
3
FAST mode
1: Yes
0: No
No
0
SEC only
4
Center No. in FAST mode
1: Host-Tel-No.
0: Service-No.
Service-No.
0
5
Maintenance cycle
Bit No.
5
6
7
75K
0
Functions in FAST
operation.
75K
0
0
1
50K
0
1
0
6
25K
0
1
1
0
20K
1
0
0
10K
1
0
1
7
5K
1
1
0
1
Free except for the
above.
8
Maintenance system
1: DM
0: AR
AR
0
S
W
4
1
Inhibited to use
1
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
5
1
Initialization control inside
program
1: The all soft switches are
initialized.
0: Does nothing.
Does nothing.
0
Used to restrict
initialization inside
the program. (Use
inhibited)
2
For FAX debug
1: Debug mode ON
0: Debug mode OFF
Debug mode OFF
0
3
Flash memory check
measuring range
1: All areas
0: 256byte
256byte
0
4
ICU UART1 output
1: Not output
0: Output
Not output
1
5
24V reset wait time
Binary
input
Bit No.
Setting range
5
6
7
8
0 to 750ms
500ms
1
6
0
7
1
8
0
S
W
6
1
Auto/Manual default setup
1: Manual reception
0: Automatic reception
Automatic
reception
0
Manual receive
setting is enabled
only when an
external telephone
is connected.
2
Inhibited to use
0
3
Size specification
Bit No.
3
4
Follows the
machine
information.
0
When setting is
made to follow the
machine
information, if the
machine information
is incomplete, the
paper size is set to
the centimeter size.
Centimeter size
0
0
Inch size
1
0
4
Follows the
machine
information.
0
1
1
Follows the
machine
information.
1
1
5
Inhibited to use
0
6
Memory transmission/
direction transmission
default setup
1: Direct transmission
0: Memory transmission
Memory
transmission
0
7
Quick memory transmission 1: Allowed
0: Inhibited
Allowed
1
8
Remote reception instruction 1: Yes
0: No
Yes
1
S
W
7
1
Remote selection number
setup
Binary input
5
0
When a value
outside the setting
value range is
inputted, the initial
value is set.
2
Bit No.
Setting range
1
2
3
4
5
6
7
8
0 to 9 times
0
3
0
4
0
5
0
6
1
7
0
8
1