AR-FX7 SOFT SWITCH 7 - 25
S
W
120
1
Scan effective image area
(SPF) rear vertial lead edge
image loss
1: –
0: +
+0 lines
0
2
Binary
input
Bit No.
Setting range
2
3
4
0 to ±56 lines
in the interval of 8 lines
0
3
0
4
0
5
Scan effective image area
(SPF) rear vertical rear edge
image loss
1: –
0: +
+0 lines
0
Since the rear edge
of the SPF cannot be
specified with
coordinates, it is
pulled after scanning,
Since the set value is
not a coordinate
value, its unit differs
from that of the other
set values. The value
cannot be increased
over the coordinates
specified in scanning.
6
Binary
input
Bit No.
Setting range
6
7
8
0 to ±14 lines
in the interval of 2 lines
0
7
0
8
0
S
W
121
1
Scan effective image area
(SPF) rear horizontal left
edge image loss
1: –
0: +
+0 dots
0
2
Binary
input
Bit No.
Setting range
2
3
4
0 to ±56 dots
in the interval of 8 dots
0
3
0
4
0
5
Scan effective image area
(SPF) rear horizontal right
edge image loss
1: –
0: +
+0 dots
0
6
Binary
input
Bit No.
Setting range
6
7
8
0 to ±56 dots
in the interval of 8 dots
0
7
0
8
0
S
W
122
1
Scan magnification ratio
adjustment SPF (horizontal)
1: –
0: +
+
0
2
Binary
input
Bit No.
Setting range
2
3
4
5
6
7
8
0 to ± 12.7%
by increment of 0.1%
0%
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
123
1
Scan magnification ratio
adjustment SPF (vertical)
1: –
0: +
+
0
2
Binary
input
Bit No.
Setting range
2
3
4
5
6
7
8
0 to ± 12.7%
by increment of 0.1%
0%
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
124
1
Print magnification ratio
adjustment rear (horizontal)
1: –
0: +
+
0
2
Binary
input
Bit No.
Setting range
2
3
4
5
6
7
8
0 to ± 12.7%
by increment of 0.1%
0%
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
125
1
Print magnification ratio
adjustment rear (vertical)
1: –
0: +
+
0
2
Binary
input
Bit No.
Setting range
2
3
4
5
6
7
8
0 to ± 12.7%
by increment of 0.1%
0%
0
3
0
4
0
5
0
6
0
7
0
8
0
SW
No.
Data
No.
Items
SW selection and functions
Default value
Remarks