AR-FX7 SOFT SWITCH 7 - 28
SW6 No. 8 Remote reception instruction
Used to set whether the remove switching function is allowed or not.
When set to 1, the function is allowed.
When set to 0, the function is not allowed.
Default: 1 (Allowed)
SW7 No.1–No.8 Remote selection number setup
Used to set the number by binary input for remote switch reception
from an external telephone. "**" in a remote switch number (X**) is
fixed.
When 10 or greater value is entered, the operations will be the same
as setup of 5.
Default: 5
SW8 No.1–No.3 Image quality priority selection
Used to set the initial value of image selection when scanning a docu-
ment.
When set to 1 0 0, the same operation as standard mode.
Default: 0 0 0 (standard)
SW8 No.4–No.8 Density default setup
Used to set the default density setup of the operation panel.
Default: 0 0 0 0 0 (automatic)
SW9 No. 1 Inhibited to use.
SW9 No. 2 Transfer function
Used to set whether transfer function is allowed or not.
Default: 1 (allowed)
SW9 No. 3 Relay broadcast function
Used to set whether the interface broadcasting command is received
from the other party to perform interface broadcasting or the interface
broadcasting command is not received from the other party.
When set to 1, the relay broadcast instruction from the allowed party is
received.
When set to 0, the relay broadcast instruction even from the allowed
party is not received.
Default: 1 (The relay broadcast instruction is received.)
Though this function is set to disable, the interface broadcasting com-
mand can be sent.
SW9 No. 4 – No.5 Inhibited to use.
SW9 No. 6 Cover function default setup
Used to set whether the cover is added or not in transmission.
When set to 1, the cover is added.
When set to 0, the cover is not added.
Default: 0 (The cover is not added.)
SW9 No. 7 Specified number reception
Used to set ON//OFF the function to reject the fax reception from the
specified numbers.
Default: 0 (Ignore specified number reception)
SW9 No. 8 Specified number reception in manual
reception
Used to set whether reception from manual reception is rejected or not
when reception function by specifying the number is ON.
Default: 1 (Reject specified number reception)
SW10 No. 1 F-code relay broadcast function
Used to set whether F code relay broadcast instruction from the other
party is received and relay broadcast transmission is performed or F
code relay broadcast instruction is not received (though the relay box
number by SUB coincides with) from the other party.
Though this function is set to disable, F code instruction can be trans-
mitted.
Default: 0 (Allowed)
SW10 No. 2 F-code confidential reception
Used to set whether F-code confidential instruction is received or not
(though the confidential box number by SUB coincides with) from the
other party.
Though this function is set to disable, F code transmission can be
made.
Default: 0 (Allowed)
SW10 No. 3 Yes/No of SUB capacity in reception
Used to set notification of YES/NO of DIS signal Bit 49 SUB capacity.
"1": No
"0": Yes
Default: 0 (YES)
If set to “1” (NO), the F code transmission from the other party can be
inhibited.
SW10 No. 4 Yes/No of SEP capacity in reception
Used to set notification of YES/NO of DIS signal Bit 47 SEP capacity.
"1": Inhibited
"0": Allowed
Default: 0 (allowed)
When set to 1 (NO), F code polling is inhibited.
SW10 No. 5 Yes/No of reception PWD capacity
Used to set whether password function is judged or not for F code bul-
letin board polling.
"1": Password is not judged. Password is disregarded and communi-
cation is allowed.
"0": Password is judged. If password is not acceptable, communica-
tion is cut off.
Default: 0 (Password is judged.)
SW10 No. 6 Yes/No of SID capacity in reception
Used to set whether password is judged or nor in F code reception.
"1": Password is not judged. Password is disregarded and communi-
cation is allowed.
"0": Password is judged. If password is not acceptable, communica-
tion is cut off.
Default: 0 (Password is judged.)
SW10 No. 7 Judgment of the system number of bulletin
board transmission
Used to set whether the condition of coincidence between the system
number of this machine and that of the other party machine is
employed as a criterion to judge whether to allow bulletin transmission
by receiving polling transmission from the other party machine made
by our company.
"1": When the system number of the other party machine made by our
company coincide with the system number of this machine, poll-
ing is allowed.
"0": Though the system number of the other party machine made by
our company coincide with the system number of this machine,
polling is inhibited.
Default: 0 (Inhibited)