AR-6020V SIMULATIONS 6-17
43
20
<26/31 CPM only>
Fusing temperature setting 3
<Fusing temperature setting 3>
With the simulation executed, the current setup values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
22
<26/31 CPM only>
Fusing temperature setting 4
<Fusing temperature setting 4>
When this simulation is executed, the current set values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
Main
code
Sub
code
Contents
Details of operation
Display
lamp
Contents
Setting Display
Setup
range
Reference
1
Ready standby TH_UM set value
O
O
1 - 99
A
2
Ready standby TH_US set value
O
O
1 - 99
B
3
Black-White plain paper TH_UM set value
O
O
1 - 99
C
4
Black-White plain paper TH_US set value
O
O
1 - 99
D
5
Fusing motor front rotation start TH-UM set value
O
O
1 - 99
E
6
Fusing motor front rotation end time
O
O
1 - 99
F
7
Warm-up complete time
O
O
1 - 99
G
8
Thin paper TH_UM set value
O
O
1 - 99
H
9
Thin paper TH_US set value
O
O
1 - 99
I
10
Heavy paper TH_UM set value
O
O
1 - 99
J
11
Heavy paper TH_US set value
O
O
1 - 99
K
12
Label paper TH_UM set value
O
O
1 - 99
L
13
Label paper TH_US set value
O
O
1 - 99
M
14
OHP TH_UM set value
O
O
1 - 99
N
15
OHP TH_US set value
O
O
1 - 99
O
16
Envelop TH_UM set value
O
O
1 - 99
P
17
Envelop TH_US set value
O
O
1 - 99
Q
18
Preheating TH_UM set value
O
O
1 - 99
R
19
Preheating TH_US set value
O
O
1 - 99
S
20
TH_UH set value when recovering from preheating
O
O
1 - 99
T
21
TH_UM set value when Warm-Up at 120 degrees or below
O
O
1 - 99
U
22
TH_US set value when Warm-Up at 120 degrees or below
O
O
1 - 99
V
23
O, P valid time (Timer from Ready state)
O
O
1 - 99
W
24
TH_UM set value when Warm-Up at 120 degree C or above
O
O
1 - 99
X
25
TH_US set value when Warm-Up at 120 degree C or above
O
O
1 - 99
Y
26
R, S valid time (Timer from Ready state)
O
O
1 - 99
Z
27
FM front rotation start TH_UM when Warm-Up at alpha
degree or above
O
O
1 - 99
AA
28
Warm-Up completion time when Warm-Up at alpha degree
or above
O
O
1 - 99
AB
29
Job approval TH_UM temperature (1) when Warm-Up at
alpha degree or above
O
O
1 - 99
AC
30
Threshold alpha applying U -W
O
O
1 - 99
AD
31
Job approval TH_UM temperature (1) when Warm-Up at
alpha degree or less
O
O
1 - 99
AE
32
Rear rotation time at the job completion time
O
O
1 - 99
AF
33
Job approval TH_UM temperature (2) when Warm-Up at
alpha degree or above
O
O
1 - 99
AG
34
Job approval TH_UM temperature (2) when Warm-Up at
alpha degree or less
O
O
1 - 99
AH
Display
lamp
Contents
Setting Display
Setup
range
Reference
1
Black-White plain paper duplex TH_UM set value
O
O
1 - 99
A
2
Black-White plain paper duplex TH_US set value
O
O
1 - 99
B
3
Applicable paper quantity of Black-White plain paper duplex
O
O
1 - 99
C
4
Black-White heavy paper duplex TH_UM set value
O
O
1 - 99
D
5
Black-White heavy paper duplex TH_US set value
O
O
1 - 99
E
6
Applicable paper quantity of Black-White heavy paper duplex
O
O
1 - 99
F
1
: ‘19/Oct.
1