AR-6020V SIMULATIONS 6-12
26
37
Cancel of stop at developer life over
When this simulation is executed, the current set code number is displayed. Enter the desired code number and
press the [START] key to set the code number. The machine goes into the sub code input state.
38
Cancel of stop at drum life over
When this simulation is executed, the current set code number is displayed. Enter the desired code number and
press the [START] key to set the code number.
39
Memory capacity check
When this simulation is executed, the current memory capacity is displayed on the number of copies display.
43
Side void amount setting
Used to set the side void amount on the both sides.
Enter a set value with the Numeric keys and press the [START] key, and the entered value will be saved and the
machine will go into the sub code input standby mode.
The setting range is 0 - 10. When the set value is increased by 1, the void amount is increased by 0.5mm. The
default is 5 (= 2.5mm).
To select the setting mode, press the [AUTO/TEXT/PHOTO] key. The set value of the selected mode is displayed
on the copy quantity display. At that time, the set value is also saved.
*
When the setting value is increased by 1, time is increased by 0.5ms.
51
Copy temporary stop function setting
When any key is pressed, it is displayed on the display section. When the [START] key is pressed, the set code
data is acquired and stored to the setting variable of sort/group copy temporary stop function and to the EEPROM.
The machine goes into the sub code input standby mode.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode
without rewriting the data. When the [CA] key is pressed, the simulation mode is terminated without rewriting the
data.
* When this is set to "Stop," temporary stop is made for every 250 copies in one copy job.
54
Life correction ON/OFF setting
Setting is made whether the image correction is made according to developer consumption degree (life progress)
or not.
When this simulation is executed, the current code number is displayed on the number of copies display.
(1=ON [Correction is performed.], 0=OFF [Correction is not performed.])
Enter the code number and press [START] key, and the setting is settled and written into the EEPROM and the
machine goes into the sub code input standby mode.
Switching can be made with [AUTO/TEXT/PHOTO] key, and the set value of the selected mode is displayed on the
number of copies display..
The setting entered at that time is written into the EEPROM.
69
Used to set the operating for toner end
This simulation used to set the operating conditions for toner end.
When this simulation is performed, the current code number is displayed.
Enter a code number and press [START] key to save the setting.
<<Operations at toner end >>
Main
code
Sub
code
Contents
Details of operation
Code number
Setting
0
1
Stop at developer life over
Cancel of stop at developer life over * Default
Code number
Setting
0
1
Stop at drum life over
Cancel of stop at drum life over * Default
Code number
Meaning (Memory capacity)
AUTO indicator
MCU memory amount
LED
Setting mode
AUTO indicator
TEXT indicator
Side void amount (Right)
Side void amount (Left)
Code number
Setting
0
1
Not stop
Stop (Default)
LED
Setting mode
Default
All OFF
Correction in the AE1 life.
1
AUTO indicator
Correction in the AE2 life
1
TEXT indicator
Correction in the TEXT life
1
PHOTO indicator
Correction in the PHOTO (Error diffusion) life
1
AUTO indicator & TEXT
indicator
Correction in the TS AE1 life.
1
AUTO indicator & PHOTO
indicator
Correction in the TS AE2 life.
1
TEXT indicator & PHOTO
indicator
Correction in the TS TEXT life
1
AUTO & TEXT & PHOTO
indicators
Correction in the PHOTO (Dither) life
1
Code number
Setting Contents
0
Operation setting 1
1
Operation setting 2
2
Operation setting 3