AR-6020V ADJUSTMENTS 5 – 2
If the distance is not within the specified range, loosen the fix-
ing screw A of the main pole adjustment plate, and move the
adjustment plate in the arrow direction to adjust.
1-C
Developing bias voltage adjustment
NOTE: Use a digital multi-meter with an internal resistance of
10Mohm or more.
1)
Execute SIM 8-1
.
2) Touch the exposure mode to be changed.
The current set value is displayed.
3) Enter the set value with the 10-key.
4) Press the [START] key.
Output is made with the entered value, and the display returns
to the original state.
<SIM8-1>
1-D
Grid bias voltage adjustment
NOTE: Use a digital multi-meter with an internal resistance of
10Mohm or more.
1)
Execute SIM 8-2
.
2)
Touch the exposure mode to be changed.
The current set value is displayed.
3)
Enter the set value with the 10-key.
4)
Press the [START] key.
Output is made with the entered value, and the display returns
to the original state.
<SIM8-2>
LED
Output mode
Setting
range
Default
AUTO indicator
COPY
0 - 650
400
TEXT indicator
COPY-TSON
0 - 650
320
PHOTO indicator
PRINTER
0 - 650
400
TEXT indicator & PHOTO
indicator
PRINTER-TSON
0 - 650
400
2
3
4
LED
Output mode
Setting
range
Default
AUTO indicator
COPY
0 - 750
540
TEXT indicator
COPY-TSON
0 - 750
460
PHOTO indicator
PRINTER
0 - 750
540
TEXT indicator & PHOTO
indicator
PRINTER-TSON
0 - 750
540
2
3
4