AR-6020V SIMULATIONS 6-22
46
29
Image contrast adjustment (600dpi)
Used to adjust the contrast for each mode.
(Operating procedure)
When this simulation is executed, warm-up and shading are performed, and the current set value is displayed in
two digits. (Default: 50)
The AUTO/TEXT/PHOTO indicators is lighted.
Change the set value and press the [START] key, and a copy is made according to the set value.
The greater the set value is, the higher the contrast is.
The smaller the set value is, the lower the contrast is.
In this case, only a copy at Exp. 3 is made.
However, the contrasts at Exp.1 and Exp. 5 are also changed accordingly.
To select a desired copy mode, press the [AUTO/TEXT/PHOTO] key.
The selected copy mode set value is displayed on the copy quantity display.
(Adjustment range: 1 ~ 99)
30
AUTO exposure limit setting
Used to set the AUTO exposure and the limit value at AUTO exposure (toner save).The set range is 0 ~ 255. The
default is 196.
Change the setting and press the [START] key, and it will be written into the EEPROM and the machine will go into
the sub code input standby mode.
Switching can be made with [AUTO/TEXT/PHOTO] key, and the set value of the selected mode is written to the
EEPROM.
<Remark>
When SIM26-06 (Destination setting) and SIM46-19 (Auto exposure mode) are changed, this set content of this
simulation is also changed to the default.
31
Image sharpness adjustment
Used to adjust clear/shading of image for each mode.
(Operating procedure)
When this simulation is executed, warm-up and shading are performed, and the current set value is displayed in
two digits. (Default: 1)
Change the set value and press the [START] key, and a copy is made according to the set value.
Use the [AUTO/TEXT/PHOTO] key to select each copy mode. The code number of the selected copy mode is
displayed on the copy quantity display .
48
01
Main scanning/sub scanning direction
magnification ratio adjustment
Used to adjust the magnification ratio in the main scanning direction (front/rear) and the sub scanning direction.
Enter the adjustment value with the Numeric keys and press the [START] key, and the entered value is saved a
copy is made.
Use the [AUTO/TEXT/PHOTO] key to select each copy mode. The code number of the selected copy mode is
displayed on the copy quantity display
(When the set value is increased by 1, the magnification ratio is increased by 0.1%.)
(Adjustment range: 1 ~ 99, Default: 50)
Main
code
Sub
code
Contents
Details of operation
LED
Copy mode
AUTO indicator
TEXT indicator
PHOTO indicator
AUTO indicator & PHOTO indicator
TEXT indicator & PHOTO indicator
AUTO indicator & TEXT indicator & PHOTO indicator
AUTO exposure mode (600dpi)
TEXT mode (600dpi)
PHOTO mode (Error diffusion)
TS mode (AUTO exposure) (600dpi)
TS mode (TEXT) (600dpi)
PHOTO mode (Dither)
LED
Setting mode
AUTO indicator
TEXT indicator
PHOTO indicator
AUTO indicator & PHOTO indicator
Limit value for OC scan AUTO exposure
Limit value for OC scan AUTO exposure (toner save)
Limit value for RSPF scan AUTO exposure
Limit value for RSPF scan AUTO exposure (toner save)
Set value
Image quality
0
1
2
Shading
Standard (Default)
Clear
LED
Copy mode
AUTO indicator
TEXT indicator
PHOTO indicator
AUTO indicator & PHOTO indicator
TEXT indicator & PHOTO indicator
AUTO indicator & TEXT indicator & PHOTO indicator
AUTO exposure mode
TEXT mode
PHOTO mode (Error diffusion)
TS mode (AUTO exposure)
TS mode (TEXT)
PHOTO mode (Dither)
LED
Adjustment mode
TEXT indicator
PHOTO indicator
Main scanning direction magnification ratio adjustment (OC/RSPF)
Sub scanning direction magnification ratio adjustment (OC)