AR-6020V SIMULATIONS 6-26
50
19
Duplex copy rear edge void adjustment
(Duplex model only)
Used to adjust the rear edge void amount in duplex copy.
(Operating procedure)
When this simulation is executed, the current set value is displayed in two digits.
(Adjustment range: 1 - 99, Center value: 50)
*
When the set value is increased by 1, the void amount is increased by about 0.1mm.
Press the [AUTO/TEXT/PHOTO] key to select a suitable setting mode and a display. Enter the adjustment value
with the Numeric keys and press the [START] key, and the entered value is saved and a copy is made. (Paper
information is cleared after every copying).
When the [INTERRUPT] key is pressed, the entered value is saved and the machine goes into the sub code entry
standby mode. When the [CA] key is pressed, the entered value is saved and the simulation is terminated.
51
01
TC ON/OFF timing adjustment
When this simulation is executed, the current set value is displayed on the number of copies display.
(Adjustment range: 1 - 99, Center value: 50)
*
When the set value is increased by 1, the void amount is increased by about 0.22mm.
Enter the adjustment value with the Numeric keys and press the [START] key, and the entered number is written
into the EEPROM and the machine goes into the sub code entry standby mode.
Switching can be made with [AUTO/TEXT/PHOTO] key, and the set value of the selected mode is displayed on the
number of copies display.
When the [INTERRUPT] key is pressed at that time, machine goes into the sub code input standby mode. When
the [CA] key is pressed, the simulation mode is terminated.
02
Resist amount adjustment
Used to adjust the contact pressure of the machine resist roller and the RSPF resist roller onto the paper.
(Operating procedure)
When this simulation is executed, the current set value is displayed on the number of copies display.
When the [START] key is pressed, the following set items are changed sequentially. Enter an adjustment value with
the Numeric keys and press the [START] key, and the entered value will be saved and a copy will be made.
(Adjustment range: 1 ~ 99)
When the [CA] key is pressed, the entered value is saved and the simulation is terminated.
Supported for the installed models only. Skipped for the models without installation.
03
<26/31 CPM only>
Used to adjust the operation timing of
the separate pawl.
Adjust the operation timing of Separate pawl.
When executing the simulation, the current set value is indicated on the display.
When pressing [Start] key after entering the code number, the entered set value is stored on EEPROM.
The set value of the selected mode is indicated on the display and the set mode can be switched by [Copy Image
Quality Mode Select] key.
The entered set values are programmed in EEPROM.
08
<26/31 CPM only>
Used to disable the operation of the
separate pawl.
Select whether to disable the operation of the separate pawl or not.
Execute the simulation to indicate the code number currently set up.
Enter the code number and press [Start] key to switch the setting.
Main
code
Sub
code
Contents
Details of operation
LED
Item
Default
AUTO indicator
TEXT indicator
PHOTO indicator
Paper rear edge void amount (First print surface)
Paper rear edge void amount (Second print surface)
Print start position (duplex back surface)
33
56
52
LED
Adjustment mode
Default
AUTO indicator
TEXT indicator
TC ON TIMING
TC OFF TIMING
50
50
No.
Contents
Setting
Display
Range
Default
1
Resist amount (Main unit cassette) (Plain paper)
O
O
1 - 99
50
2
Resist amount (2nd to 4th cassette) (Plain paper)
O
O
1 - 99
50
3
Resist amount (Second print surface) (Plain paper)
O
O
1 - 99
50
4
Resist amount (Manual feed tray) (Plain paper/Thin paper)
O
O
1 - 99
65
5
Resist amount (Manual feed tray) (Heavy paper 1)
O
O
1 - 99
50
6
Resist amount (Manual feed tray) (Heavy paper 2)
O
O
1 - 99
50
7
Resist amount (Manual feed tray) (Envelop)
O
O
1 - 99
50
8
Resist amount (Manual feed tray) (OHP)
O
O
1 - 99
50
9
Resist amount (Manual feed tray) (Label)
O
O
1 - 99
50
10
Resist amount (Manual feed tray) (Letter)
O
O
1 - 99
50
11
RSPF document resist amount (First print surface) (Low
speed)
O
O
1 - 99
50
12
RSPF document resist amount (First print surface) (Low
speed)
O
O
1 - 99
50
13
RSPF document resist amount (First print surface) (High
speed)
O
O
1 - 99
50
14
RSPF document resist amount (First print surface) (High
speed)
O
O
1 - 99
50
Lighting LED
Set mode
AUTO LED
TEXT LED
Time setting of Solenoid ON
Time setting of Solenoid OFF
Code Number
Setting
0
1
ENABLE
DISABLE
1
: ‘19/Oct.
1