10
Product Version 1.0 | Revision E | Released 2022-12-09
RIGGING PROCESS USING SGM OMEGA BRACKETS
Start the standard rigging process by blocking the lower working area, and make sure the work is performed from a
stable platform.
1. Check that the clamp/bracket is undamaged. Supporting structure should be capable of bearing at least 10
times the weight of all installed fixtures, lamps, cables etc.
2. Bolt a clamp or bracket securely to the omega bracket with a M12 bolt (min. grade 8.8) and a lock nut. For
longer term installations, choose outdoor rated hardware.
3. Align the omega bracket with the fixture base. For standard Omega Bracket, insert the fasteners into the fix-
ture base bracket, and turn both levers a full 1/4 turn clockwise to lock. When using the POI Omega Bracket,
insert the included M-10 screws through the bracket holes and tighten them with a M-10 key until they are
Figure 3.1 : Installing the P-6
Figure 3.2 : Installing the P-6
Figure 2: Dimensions for base locking points
WARNING! ALWAYS USE MIN. 2 OMEGA BRACKETS WHEN RIGGING THE FIXTURE.
Omega bracket
Holes for omega bracket
159mm
6,26in
106mm
4,17in
401mm
15,77in
111mm
4,37in
159mm
6,26in