9
Product Version 1.0 | Revision E | Released 2022-12-09
UNPACKING
Unpack the device and inspect it to ensure that it has not been damaged during transport.
The fixture is shipped with:
• 2 x Omega bracket with 1/4-turn fasteners (standard only).
• 1 x Power cable with IP connector, 2 m./ 78 in
• Safety information leaflet.
• Application considerations
APPLICATION CONSIDERATIONS
The standard fixture is IP65-rated and is designed for both indoor and outdoor events. This means that it is protected
from:
• Dust, to the degree that dust cannot enter the fixture in sufficient quantities as to interfere with its operation.
• Lower pressure water jets from any direction.
When using standard fixtures outdoors or in wet locations, ensure that:
• The DMX connection out of the last fixture in a chain is properly sealed, in accordance with the ingress protec-
tion (IP) requirements.
• The DMX out of the last fixture is terminated with a 120 Ohm resistor between pin 2 and 3 (as per RS485 stand-
ards).
When selecting a location for the device, ensure that:
• It is situated away from public thoroughfares and protected from contact with people.
• It has adequate ventilation.
• It is not immersed or submerged in water.
TRANSPORT HANDLING
Always use the supplied packaging or suitable flight case for transportation and storage. Never carry the fixture by
connected cables or wires.
The fixture may be installed in any orientation, on the ceiling or on a
wall surface.
When installed horizontally with a downward beam-angle, water or dirt
can potentially pool in the fan wells. Under normal operation the mois-
ture will evaporate.
In locations with high rainfall, consider locating the fixture under cover
or an overhang, or modify the position and orientation of the fixture to
minimize pooling.
All SGM fixtures have locking points in the base for installation and rig-
ging. In both standard and POI fixtures, the distance between the
points from center to center is always 106 mm. Standard versions in-
clude 1/4 turn fasteners to mount SGM omega brackets. POI versions
come with M-10 captive nuts for M-10 screws.
Always use the supplied omega bracket to rig a standard fixture. Lock
the bracket with the 1/4-turn fasteners.
PLEASE NOTE! 1/4-TURN FASTENERS ARE ONLY LOCKED WHEN TURNED FULLY CLOCKWISE. DEPENDING ON
THE STRUCTURE, PLEASE USE APPROPRIATE AND SECURE METHODS FOR MOUNTING THE OMEGA BRACKETS.
RIGGING
106 mm
[ 4,2in ]
Ø 18 mm
[ 0,7in ]
Figure 1: Locking points