background image

27

SIA Communications For Skyroute(continued)

Event Description

SIA Message

Zone# Identified

Duress Alarm

HA00

Opening After Alarm

OR00

Keypad [F]ire

FAzz/FHzz

Yes

Keypad [A]uxiliary

MAzz/MHzz

Yes

Keypad [P]anic

PAzz/PHzz

Yes

PGM2:

2 Wire Smoke

FA99/FH99

Audible 24 Hour

UA99/UH99

Silent 24 Hour

UA99/UH99

Zone Tamper (1-32)

TAzz

Yes

Zone Tamper Restorals (1-32)

TRzz

Yes

General System Tamper / Restore

TA00/TR00

Closing by Access Codes

CLus

Yes

(1-32,33,34,40,41,42)
Partial Closing

CGus

   Yes (using UBzz)

Opening by Access Codes

OPus

Yes

(1-32,33,34,40,41,42)
Battery Trouble

YT00/YR00

AC Failure Trouble

AT00/AR00

Bell Circuit Trouble

UT99/UJ99

Fire Trouble

FT00/FJ00

Auxiliary Power Supply Trouble

YP00/YQ00

TLM Trouble Code (via Skyroute)

LT00

General System Supervisory / Restore

ET00/ER00

General System Trouble / Restore

YX00/YZ00

TLM Restoral

LR00

FTC Fail / FTC Restoral

YC00/YK00

Event Buffer 75% Full Since Last Upload

JL00

Periodic Test Transmission

RP00

System Test

RX00

Skyroute Test Transmission Code

TX00

     Signal Strength

Zone Fault Alarm/Restoral

UTzz/UJzz

1

Yes

Burglary Verified

BV00

Delinquency Code

CD00

Zone Low Battery

XTzz/XRzz

2

Yes

Recent Closing

CR00

User NOT Identified

Zone Expander Supervisory

UA00/UH00

Keypad Lockout

JA00

Special Closing (DLS, Keys, Maint, Quick)

CLus

        Yes (User)

Special Opening (DLS, Keys, Maint)

OPus

        Yes (User)

DLS Lead In

RB00

DLS Lead Out (Successful)

RS00

Auto-Arm Cancellation

CE00

Late to Close

CI00

Skyroute Tamper Cut

TAzz/TRzz

Yes

Keybus Cut

USzz/URzz

Yes

Telephone Line Cut

LTln/LRln

Expansion Device

ETex/ERex

Summary of Contents for Skyroute UT

Page 1: ...Installation Manual...

Page 2: ...one Line Monitor TLM 10 4 3 Swinger Shutdown 10 4 4 Skyroute Programming Sections 803 11 Activating the Skyroute Transceiver 12 Calling Connect 24 12 Skyroute Transceiver Trouble Supervision 12 Skyrou...

Page 3: ...rogrammable zone attributes Normally closed single EOL Audible Alarm Output 700mA Supervised Bell Output current limited at 3 amps 12VDC Steady or Pulsed Output EEPROM Memory Does not lose programming...

Page 4: ...ng PC5400 serial interface module or viewed with the LCD5500Z keypad and DLS 1 software Uploading and downloading capability Antenna 3 5 dB gain TNC connector Extension Kits available LAE 3 The 3 Foot...

Page 5: ...or applying AC to the panel Step 2 Mounting the Skyroute Transceiver The Skyroute Transceiver can be mounted in the upper right hand corner of the panel cabinet through the knock out The Skyroute Tra...

Page 6: ...erminal Descriptions Battery Connection A 12V 7Ah rechargeable battery is used as a backup source of power in the event of an AC power failure The battery also provides additional current when the pan...

Page 7: ...UX the negative side to PGM1 PGM2 operates similarly to PGM1 If more than 50 mA of current are required a relay must be used For a list of the programmable output options please see section the PGM Ou...

Page 8: ...el communicator to telephone lines intended for use with a fax machine These lines may incorporate a voice filter which disconnects the line if anything other than fax signals are detected resulting i...

Page 9: ...t with the mounting bracket Remove the antenna from the Skyroute module and connect the extension cable to the TNC connector on the module Secure the antenna to the TNC connector mounted on the Extens...

Page 10: ...Decimal Data A set number of programming boxes are allotted for each section requiring decimal data e g codes telephone numbers If a digit is entered for each program box the panel will automatically...

Page 11: ...iately display all the information programmed in that section Use the arrow keys to scroll through the data being displayed Scroll past the end of the data displayed or press the key to exit the secti...

Page 12: ...eiver SID System ID Sub Section 07 The chart below lists the different System ID for each of the territories For proper activation of the Skyroute Transceiver the correct SID for the territory that yo...

Page 13: ...when the Skyroute Transceiver is on stand by ready to transmit mode Troubles are indicated when LED5 flashes more than once every second Shown below is the number of flashes used to indicate each tro...

Page 14: ...09 System Trouble Output The PGM output will activate when any of the selected trouble conditions are present It will deactivate when all the selected trouble conditions are cleared The PGM attribute...

Page 15: ...wer NOTE If you program more than one PGM output as the same output type e g if PGM1 and PGM2 are both programmed as 19 Command Output 1 the settings for output attributes 1 2 and 5 must be the same T...

Page 16: ...When the keypad is again operational the default is complete Restore Panel to Default Programming Section 999 4 8 Installer s Lockout Installer code If Installer s Lockout is selected a hardware defa...

Page 17: ...M 2 015 Third System Option Code Default Option ON OFF Section ON I________I 7 TLM Enabled TLM Disabled 370 Communication Variables Default Section 003 I_______I_______I_______I Swinger Shutdown Alarm...

Page 18: ...N I_____I Option 2 B Channel Selected B Channel Not Selected OFF I_____I Option 3 Home System Only Not in Home System Operation OFF I_____I Options 4 to 8 For Future Use 07 Home SID Number 0000 I_____...

Page 19: ...to 78 if 00 is entered then that reporting code is disabled If FF is in the section then the reporting code is enabled FF is the default value 30 Alarm Reporting Codes Zones 1 8 Default Default FF I__...

Page 20: ...__I General System Trouble Restore FF I_____I_____I Fire Trouble Restoral FF I_____I_____I General System Supervisory Restore 77 Miscellaneous Maintenance Restoral Reporting Codes FF I_____I_____I Pho...

Page 21: ...20 Skyroute UT Antenna Cable Installation...

Page 22: ...Z3 COM COM Z2 Z4 RING TIP R 1 T 1 EGND PGM 1 2 SI S0 Connection for PC Link Max Min Rx Tx Status Indicator Signal Strength Indicator LED 1 LED 2 LED 3 LED 4 LED 5 GRN RED BLK YEL COM BELL OUT BELL IN...

Page 23: ...AUX AC YEL GRN Z1 Z3 COM COM Z2 Z4 RING TIP R 1 T 1 EGND PGM 1 2 SI S0 Connection for PC Link Max Min Rx Tx Status Indicator Signal Strength Indicator LED 1 LED 2 LED 3 LED 4 LED 5 GRN RED BLK YEL CO...

Page 24: ...PC580 BELL AUX AC YEL GRN Z1 Z3 COM COM Z2 Z4 RING TIP R 1 T 1 EGND PGM 1 2 SI S0 Connection for PC Link Max Min Rx Tx Status Indicator Signal Strength Indicator LED 1 LED 2 LED 3 LED 4 LED 5 GRN RED...

Page 25: ...t Ground Rod PC580 BELL AUX AC YEL GRN Z1 Z3 COM COM Z2 Z4 RING TIP R 1 T 1 EGND PGM 1 2 SI S0 Connection for PC Link Max Min Rx Tx Status Indicator Signal Strength Indicator LED 1 LED 2 LED 3 LED 4 L...

Page 26: ...Bell Positive Siren Trigger Bell always to ground and Bell switch to on alarm With this configuration Zx1 will be trigger every time the Bell is activated ORG RED BLK Bell Bell GND Zx COM BRG GND 120...

Page 27: ...ed Null Zone Not used Delay 1 BAzz BHzz Yes Delay 2 BAzz BHzz Yes Instant BAzz BHzz Yes Interior BAzz BHzz Yes Delay H A BAzz BHzz Yes Interior H A BAzz BHzz Yes 24 Hr Burglary BAzz BHzz Yes Standard...

Page 28: ...ower Supply Trouble YP00 YQ00 TLM Trouble Code via Skyroute LT00 General System Supervisory Restore ET00 ER00 General System Trouble Restore YX00 YZ00 TLM Restoral LR00 FTC Fail FTC Restoral YC00 YK00...

Page 29: ......

Page 30: ...erson purporting to act on its behalf to modify or to change this warranty nor to assume for it any other warranty or liability concerning this product In no event shall Sur Gard Ltd be liable for any...

Reviews: