![SFA SANISUB S ZPK Operating & Installation Manual Download Page 8](http://html1.mh-extra.com/html/sfa/sanisub-s-zpk/sanisub-s-zpk_operating-and-installation-manual_1250835008.webp)
8
EN
1. SAFETY
IDENTIFICATION OF WARNING
Meaning
DANGER
This term defines a high-risk hazard that can lead to
death or serious injury if not avoided.
WARNING
This term defines a medium risk of danger, which
can lead to serious or minor injury, if not avoided.
CAUTION
Ce terme définit un danger à risques faibles pouvant
conduire à des blessures mineures s’il n’est pas évité.
NOTICE
This term defines a low risk of danger which can
lead to minor injuries if not avoided.
Warning of a general danger.
The danger is specified by indications given in the
table.
This symbol characterises dangers associated with
the voltage and provides information on voltage
protection.
• Only use the pumping station in the applications described in this
documentation.
•
The pumping station must never operate without pumped fluid.
•
Any alteration or modification of the pumping station will render
the warranty void.
• This operating manual must always be available on the site so it
can be accessed by qualified staff and the operator.
• Failure to comply with this operating and installation manual will
result in the loss of warranty rights and rights to damages.
2. TRANSPORT, DISPOSAL
2.1 TRANSPORT
• Prior to commissioning, check the pump for possible external
damages (e.g. transport damages) in order to prevent accidents
with electrical current.
• Never hang up the pumping station by the electric cable.
2.2 DISPOSAL
The device must not be disposed of as household waste and
must be disposed of at a recycling point for electrical equip-
ment. The device’s materials and components are reusable.
The disposal of electrical and electronic waste, recycling
and recovery of any form of used appliances contribute to
the preservarion of our environment.
3. DESCRIPTION
3.1 APPLICATIONS
Sanisub (S) ZPK
is suitable for conveying slightly contaminated
water with suspended solids (no rocks) from private households or
commercial use. Domestic grey water is allowed in discharge sys-
tem.
The size of suspended solids must not exceed:
- 10 mm (
Sanisub (S) ZPK
30
),
- 30 mm (
Sanisub (S) ZPK
40
).
Sanisub S ZPK
series pumps are suitable for salt water (sea water,
water from water softeners, etc.)
WARNING
Pumping unauthorised fluids.
Dangerous for people and the environment!
Only discharge authorised pumped fluids in the public sew
-
erage network.
Unauthorised pumped fluids:
- waste waters containing substances which attack or damage the
pump’s materials.
- waste waters containing faeces (black water).
- Wastewater containing harmful substances (for example, untreat-
ed greasy waste from restaurants). Pumping these liquids and sub-
stances requires the fitting of a compliant grease trap.
3.2 OPERATING PRINCIPLE
When the level of effluent in the concrete manhole or pit where the
Sanisub (S) ZPK
is installed is sufficient, the float switch switches
the lifting pump on.
The effluent is automatically lifted to flow into the sewer line. When
the water level drops to a low level, the float switch goes down and
switches the pump off.
3.3 TECHNICAL DATA
Sanisub
ZPK 30 A
S ZPK 30 A
ZPK 40 A
S ZPK 40 A
ZPK 40 AV
Power rating P1
300 W
850 W
Voltage
230 V
Frequency
50 Hz
Maximum current
1.3 A
3.7 A
Speed rotation
2800 tr.min-1
Max. discharge flow rate
Qmax
7.0 m³/h
10.0 m³/h
Max. discharge height Hmax
7,5 m
10 m
Max. liquid temperature
40 °C continuously, 90°C (5 min max)
ON level
depending on the float cable
length
200-240 mm
OFF level
100-180 mm
Discharge connection
1-1/4"
Diameter
150 mm
Total height
270 mm
345 mm
Supply cable
10 m with plug
Weight with cable
4.4 kg
6.6 kg
Max. submersion depth
5 m
Minimum liquid level
120 mm
200 mm
Max. particle size
10 mm
30 mm
Float switch
yes, with cable
yes, vertical
Length of the float cable
400 mm
-
Materials
Motor housing
Stainless steel
Pump housing
PP GF
Mechanical seal
Carbon/ceramic (+ Viton/Teflon S ZPK-series)
Impeller
PA 6 GF
Shaft
Stainless steel
Screws
Stainless steel
Strainer
Polyethylen (PE)
Float switch
Polypropylen (PP)
3.4 SCOPE OF SUPPLY
- 90° 1-1/4" threaded connection elbow for connection of a DN25
(
Sanisub (S) ZPK
30
) or DN32 (
Sanisub (S) ZPK
40
) pipe, non
return valve,
-
Sanisub (S) ZPK
A
: float switch,
-
Sanisub (S) ZPK
AV
: compact vertical float switch.
3.5 DIMENSIONS
Sanisub (S) ZPK
30 A
Sanisub (S) ZPK
40 A
Sanisub ZPK
40 AV
Summary of Contents for SANISUB S ZPK
Page 26: ...Notes...
Page 27: ......