5
Electrical installation
Hybrid ABOX MTA...-I55.-...-00, MTA...-G55.-...-00
Operating Instructions – MOVIFIT
®
FC
92
5.11
Hybrid ABOX MTA...-I55.-...-00, MTA...-G55.-...-00
INFORMATION
• The hybrid ABOX is based on the standard ABOX MTA...-S02.-...-00. The follow-
ing therefore only describes the additional plug connectors in comparison with the
standard ABOX.
• For a description of the terminals, refer to chapter "Standard ABOX MTA...-
• In contrast to the standard ABOX, the hybrid ABOXes MTA...-I55.-...-00 and
MTA...-G55.-...-00 have no shield plates. Here, the cable shields must be connec-
ted via EMC cable glands.
• Customers cannot use terminal strips X8, X81, X25, X30 and X31 in the ABOX
because the described plug connectors are assigned to them.
5.11.1
Description
The following figure shows the hybrid ABOX with:
• 1 circular connector (Intercontec):
– Motor output pointing downward (only for MTA...-I55.-...-00)
– Motor output pointing forward (only for MTA...-G55.-...-00)
• M12 plug connectors for digital inputs/outputs
• M12 plug connectors for the fieldbus
X80
[3]
[2]
[1]
[4]
[3]
[5]
[6]
X21
X25
X26
X27
X28
X22
X11
X80
X12
X23
X24
MTA...-G55.-...-00
MTA...-I55.-...-00
18014403265392907
[1]
Maintenance switch (optional)
[2]
PE connection
[3]
Plug connector for motor
[4]
M12 plug connector for digital inputs/outputs
[5]
Diagnostics socket (RJ10) under the screw plug
[6]
M12 plug connectors for the fieldbus connection
21316996/EN – 12/2014