Mechanical installation
Installation
Operating Instructions – MOVIFIT
®
FC
33
Drilling template for mounting rail (POF option L10)
The MOVIFIT
®
unit with the special mounting rail is mounted in the same way as a unit
with /M11 mounting rail.
For the special mounting rail, an additional retaining screw is required behind the POF
option, see the figure below.
6
3
66
136
1
4
0
4
0
5
0
5
0
1
5
3
7
.5
410.3
min. 50
mi
n
.
4
0
[2]
[1]
3
3
2
.3
[3]
mi
n
.
1
0
4
9007204017858571
• [1] Observe the minimum installation clearance so that the EBOX can be removed
from the ABOX.
• [2] Observe the minimum installation clearance required to operate the mainte-
nance switch and to ensure heat dissipation for the unit.
• Make sure that the permitted bending radii of the cables used is not exceeded
when connecting the cables.
• [3] For all ABOXes with round connector (Intercontec) and downward motor output,
observe the minimum clearance of 104 mm to the bottom of the ABOX.
• For all ABOXes with round connector (Intercontec) and motor output at the front,
observe the minimum clearance of 191 mm at the front of the ABOX.
For detailed dimension drawings, refer to chapter "Technical data" > "Dimension draw-
ings".
21316996/EN – 12/2014