6
Startup
Description of the DIP switches
Operating Instructions – MOVIFIT
®
FC
135
MTF..-17
DRP
V = AC 3 x 460 V, 60 Hz
MOVIFIT
®
Assigned motor and brake
1)
S10/5 = OFF
S10/5 = ON
W
connection
m
connection
W
connection
m
connection
Motor
Brake
Motor
Brake
Motor
Brake
Motor
Brake
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
MTF..003..-17 -
-
-
-
-
-
-
-
-
-
-
-
MTF..005..-17 -
-
-
-
-
-
-
-
-
-
-
-
MTF..007..-17 DRP90M4
BE1
BE2 -
-
-
-
-
-
-
-
-
MTF..011..-17 DRP90L4
1.1 kW
BE2
BE1 DRP90M4
BE1
BE2 DRP90M4
BE1
BE2 -
-
-
MTF..015..-17 DRP90L4
1.5 kW
BE2
BE1 DRP90L4
1.1 kW
BE2
BE1 DRP90L4
1.1 kW
BE2
BE1 DRP90M4
BE1
BE2
MTF..022..-17 DRP112M4
BE5
BE11 DRP90L4
1.5 kW
BE2
BE1 DRP90L4
1.5 kW
BE2
BE1 DRP90L4
1.1 kW
BE2
BE1
MTF..030..-17 DRP132S4
BE5
BE11 DRP112M4
BE5
BE11 DRP112M4
BE5
BE11 DRP90L4
1.5 kW
BE2
BE1
MTF..040..-17 -
-
-
-
-
-
DRP132S4
BE5
BE11 DRP112M4
BE5
BE11
1) Possible brake voltages: 120 V, 230 V, 400 V
MTF..-18
DRN
V = AC 3 x 400 V, 50 Hz
MOVIFIT
®
Assigned motor and brake
1)
S10/5 = OFF
S10/5 = ON
W
connection
m
connection
W
connection
m
connection
Motor
Brake
Motor
Brake
Motor
Brake
Motor
Brake
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
MTF..003..-18 -
-
-
-
-
-
-
-
-
-
-
-
MTF..005..-18 -
-
-
-
-
-
-
-
-
-
-
-
MTF..007..-18 DRN80M4
BE1
BE05 -
-
-
-
-
-
-
-
-
MTF..011..-18 DRN90S4
BE2
BE1 DRN80M4
BE1
BE05 DRN80M4
BE1
BE05 -
-
-
MTF..015..-18 DRN90L4
BE2
BE1 DRN90S4
BE2
BE1 DRN90S4
BE2
BE1 DRN80M4
BE1
BE05
MTF..022..-18 DRN100LS4
BE5
BE2 DRN90L4
BE2
BE1 DRN90L4
BE2
BE1 DRN90S4
BE2
BE1
MTF..030..-18 DRN100L4
BE5
BE2 DRN100LS4
BE5
BE2 DRN100LS4
BE5
BE2 DRN90L4
BE2
BE1
MTF..040..-18 DRN112M4
BE5
BE11 DRN100L4
BE5
BE2 DRN100L4
BE5
BE2 DRN100LS4
BE5
BE2
1) Possible brake voltages: 120 V, 230 V, 400 V