Startup
Starting up the MOVIFIT® frequency inverter
Operating Instructions – MOVIFIT
®
FC
143
6.6
Starting up MOVIFIT
®
frequency inverter
Starting up
the
MOVIFIT®
frequency
inverter
6.6.1
Startup mode
You can use one of the following startup modes to start up the MOVIFIT
®
frequency
inverter:
• MOVIFIT
®
FC can be started up quickly and easily in
Easy mode
using DIP switch
S10.
• Activate the
Expert mode
by setting DIP switch S10/1 to "ON". In "Expert" mode
additional parameters are available. You can use the MOVITOOLS
®
MotionStudio
software to adjust the parameters to the application (Function level "Technology"
and "Classic").
• After activating Expert mode, the MOVIFIT
®
unit and its parameters are initialized
once according to the setting of DIP switches S10/2 to S10/6.
• While Expert mode is active, DIP switches S10/2 to S10/6 are only re-effected
when you set the
P802 Factory setting
parameter to "Delivery state". Otherwise,
the system will ignore the changing of the DIP switch setting.
6.6.2
Startup in Easy mode
1. Set DIP switch S10/1 to "OFF".
ON
1 2 3 4 5 6
S10
2. Set the device parameters using DIP switches S10/2 to S10/6, see chapter "De-
scription of DIP switches" > "DIP switch S10" (
3. Place the EBOX onto the ABOX and close it.
4. Switch on the 24 V supply voltage. The "24V_C" LED should now light up green.
Easy motor startup is now enabled; no further measures are required.
6.6.3
Starting up MOVIFIT
®
drive with constant voltage brake
INFORMATION
• When you connect a MOVIFIT
®
drive with a constant voltage brake, note the spe-
cific terminal assignment for connecting the brake as specified in chapter "Stand-
ard ABOX... " > "Terminal assignment" > "Motor terminals" (
• For tips on starting up the MOVIFIT
®
drive with a constant voltage brake, refer to
the " MOVIFIT
®
Function Level Technology..." manual.
21316996/EN – 12/2014