6
Startup
Parameterization with the MBBG11A operator panel
Operating Instructions – MOVIFIT
®
compact
57
6.6.5
Data backup
SEW-EURODRIVE recommends backing up the data set after startup. The data set
can then be re-used for other MOVIFIT
®
compact devices with identical motors. Switch
from the main menu to the data backup menu. The data backup menu provides 2
functions:
•
Save the data set from the MOVIFIT
®
compact device in the MBBG11A operator
panel (display: "StorE").
•
Load the data set from the MBBG11A operator panel to the MOVIFIT
®
compact
device (display: "rECAL").
The following illustration shows the menu guidance of the data backup menu:
Enter
Save the data set from
the MOVIFIT
®
compact
device in the MBBG11A
operator panel.
S t A r t
out
Enter
out
Enter
C O P Y
S t o r E
n o
Enter
Load the data set from
the MBBG11A operator
panel to the MOVIFIT
®
compact device.
S t A r t
out
Enter
r E C A L
n o
Saving the data set from the MOVIFIT
®
compact device in the MBBG11A operator panel
Save the data set in the MBBG11A operator panel as shown in the menu guidance
above. During the saving process, the MBBG11A operator panel displays “u.u.”.
After saving, the following appears for 1 second:
•
The positive acknowledgment “donE“
•
or an error code in the form “r-xx“.
Then “no“ is displayed again.
If you press the <OUT> key twice, you return to the main menu.
Loading the data set from the MBBG11 operator panel to the MOVIFIT
®
compact device
The data set can only be loaded to the MOVIFIT
®
compact device in “No enable” oper-
ating state.
Load the data set to the MOVIFIT
®
compact as shown in the menu guidance above.
During the saving process, the MBBG11A operator panel displays “d. d.”.
After saving, the following appears for 1 second:
•
The positive acknowledgment “donE“
•
or an error code in the form “r-xx“.
Then “no“ is displayed again.
To enable the MOVIFIT
®
compact again, press the <RUN> key.
22527060/EN – 08/2017