6
Startup
Startup procedure for MOVIFIT® compact motor starter
Operating Instructions – MOVIFIT
®
compact
47
6.4
Startup procedure for MOVIFIT
®
compact motor starter
Startup
procedure
for
MOVIFIT®
compact
motor
starter
To start up the motor starter, proceed as follows:
1. Check the connection of the MOVIFIT
®
compact device.
ð
See chapter "Electrical installation".
2. Ensure that the motor does not start up, and that there is no hazard from an un-
wanted motor startup.
3. Switch on the line voltage. The “STATUS” LED illuminates in yellow.
4. Connect the MBBG11A operator panel or PC/laptop to the MOVIFIT
®
compact
device.
ð
See chapter "Connecting the MBBG11A operator panel"
ð
or chapter "Connecting a PC/laptop".
5. For a simple startup, set the parameters of the motor as described in the following
chapters. The following operating modes are available in the MOVIFIT
®
compact
motor starter for operating an asynchronous motor:
ð
Voltage limiting
ð
Current limiting
6.
NOTICE!
Loss of the ensured degree of protection if the screw plug is not installed
or not installed correctly on the diagnostic interface. Damage to the MOVIFIT
®
compact device.
Make sure the screw plug of the diagnostic interface has a seal and screw it in.
7. Switch off the line voltage.
8. Set the AS-Interface slave address of the MOVIFIT
®
compact device (only
with MOVIFIT
®
compact with AS-Interface).
ð
See chapter "Assigning the AS-Interface slave address".
9. Start up the higher-level controller.
10. Connect the plug of the motor to the MOVIFIT
®
compact.
11. Switch on the line voltage.
The MOVIFIT
®
compact drive can now be controlled using the higher-level controller
(binary signals or via AS-Interface).
22527060/EN – 08/2017