![SEW-Eurodrive MOVI-C UHX45A Series Manual Download Page 82](http://html.mh-extra.com/html/sew-eurodrive/movi-c-uhx45a-series/movi-c-uhx45a-series_manual_1250103082.webp)
8
Technical data
Compact controller
Manual – MOVI-C
®
CONTROLLER advanced with PROFINET IO Fieldbus Interface
82
8.3
Compact controller
MOVI‑C
®
CONTROLLER advanced UHX45A
Electrical supply
•
Power consumption: P
max
= 12 W
•
Supply voltage V = DC 24 V (-15% / +20%)
according to IEC 61131‑2
•
Current consumption I
max
= 500 mA
(with DC 24 V supply voltage)
•
The MOVI-C
®
CONTROLLER has to be supplied by an ex-
ternal voltage source.
Memory
•
Retain data: 32 kB
•
Retain persistent: 2 kB
•
Program memory: 2 MB for application, including IEC lib-
raries
•
Data memory: 6 MB
OMH45A SD memory card in the XM SD
card slot
•
PC-readable
•
Contents:
– Firmware
– IEC program
– Application data
•
512 MB memory
X5
DC 24 V supply voltage connection (2-pin
connection)
Connection type: Plug connector
•
1 core: 0.25 mm
2
– 2.5 mm
2
•
2 cores: 0.5 mm
2
– 1.5 mm
2
(TWIN‑AEH
1)
)
X30 (RJ45 socket)
EtherCAT
®
/SBus
PLUS
interface
Fast system bus SBus
PLUS
based on EtherCAT
®
for master
connection
X40/X41
fieldbus interface
(RJ45 socket)
Fieldbus interfaces for slave connection:
•
MOVI‑C
®
CONTROLLER UHX45A‑N: PROFINET IO
•
MOVI‑C
®
CONTROLLER UHX45A‑E: EtherNet/IP™ or
Modbus TCP (in preparation)
X80/X81
Engineering interface
(RJ45 socket)
•
TCP/IP
•
Possible connections: Engineering PC, visualization, other
controller
•
Engineering for all SEW‑EURODRIVE components con-
nected to the MOVI-C
®
CONTROLLER can be performed
via the MOVI-C
®
CONTROLLER.
X85
System bus and RS485 interface
(9-pin connection)
Connection type: Plug connector, 1 core: 0.25 mm
2
–
0.75 mm
2
1) AEH: Conductor end sleeve
24777730/EN – 01/2018