8
Technical data
General
Manual – MOVI-C
®
CONTROLLER advanced with PROFINET IO Fieldbus Interface
81
8.2
General
General technical data
Interference immunity
Meets EN 61800-3; 2. Environment
Interference emission
Limit value category C2 to EN 61800‑3
Ambient temperature ϑ
amb
0 °C – +60 °C
Type of cooling
Convection cooling
Environmental conditions
Climatic requirements
•
Extended storage:
EN 60721-3-1 class 1K2 temperature -25 °C – +70 °C
•
Transportation:
EN 60721-3-2 class 2K3 temperature -25 °C – +70 °C
•
Operation (fixed installation, weatherproof):
EN 60721-3-3 class 3K3 temperature 0 °C – +60 °C
Chemically active substances
•
Extended storage:
EN 60721-3-1 class 1C2
•
Transportation:
EN 60721-3-2 class 2C2
•
Operation (fixed installation, weatherproof):
EN 60721-3-3 class 3C2
Mechanically active substances
•
Extended storage:
EN 60721-3-3 class 1S1
•
Transportation:
EN 60721-3-3 class 2S1
•
Operation (fixed installation, weatherproof):
EN 60721-3-3 class 3S1
Vibration testing
•
3M5 according to EN 60721-3-3
•
5M1 according to EN 60721-3-5
Degree of protection
Degree of protection
IP20 according to EN 60529
Pollution class
2 according to IEC 60664-1
Overvoltage category
III according to IEC 60664-1
Installation altitude
Maximum 3800 m (above sea level)
24777730/EN – 01/2018