
6
Appendix
Description of the access points
Manual – ECDriveS
®
40
6.1.5
Input data "ZPA mode"
Process
data word
[PI]
Data
type
Designation
Bytewise
notation
[byte.bit]
Wordwise
notation
[word.bit]
Description
0
Byte
StateUpstreamZoneInverce
0.0
0.7
0.0
0.15
Status of the upstream zone of the fieldbus controller in
ZPA mode with inverted direction of flow (current direc-
tion of flow ≠ configured direction of flow). Description of
the transfered data corresponds to 1 byte (StateUp-
streamZone)
Byte
StateUpstreamZone
1.0
1.7
Status of the upstream zone of the fieldbus controller in
ZPA mode:
Value 0x01
Empty
: There is no material to be con-
veyed in the zone and no material is arriving from the
upstream zone (sensor free, motor not enabled)
Value 0x02
Accepting:
Zone is empty, but material to
be conveyed is arriving from the upstream zone (sensor
free, motor enabled)
Value 0x04
:
Full and Running
: There is material to be
conveyed in the zone and it is being conveyed in the dir-
ection of the downstream zone (sensor occupied, motor
enabled)
Value 0x05
Full and Stopped
: There is material to be
conveyed in the zone and it is being accumulated there
(sensor occupied, motor not enabled)
1
Byte
StateDownstreamZoneInverce
2.0
2.7
1.0
1.15
Status of the downstream zone of the fieldbus controller
in ZPA mode with inverted direction of flow (current dir-
ection of flow ≠ configured direction of flow). Description
of the transfered data corresponds to 1 byte (StateUp-
streamZone)
Byte
StateDownstreamZone
3.0
3.7
Status of the downstream zone of the fieldbus controller
in ZPA mode:
Value 0x01
Empty
: There is no material to be con-
veyed in the zone and no material is arriving from the
upstream zone (sensor free, motor not enabled)
Value 0x02
Accepting:
Zone is empty, but material to
be conveyed is arriving from the upstream zone (sensor
free, motor enabled)
Value 0x04
Full and Running
: There is material to be
conveyed in the zone and it is being conveyed in the dir-
ection of the downstream zone (sensor occupied, motor
enabled)
Value 0x05
:
Full and Stopped
: There is material to be
conveyed in the zone and it is being accumulated there
(sensor occupied, motor not enabled)
2
Int
ArrivalCounterUpstreamZone
4.0
4.7
2.0
2.15
This word is increased by 1 every time that material be-
ing conveyed arrives in the upstream zone. The over-
flow takes place when the value 65535 is reached. The
counter is reset to 0
5.0
5.7
3
Int
DisarrivalCounterUp-
streamZone
6.0
6.7
3.0
3.15
This process data word is increased every time that ma-
terial being conveyed leaves the upstream zone. The
overflow takes place when the value 65535 is reached.
The counter is reset to 0
7.0
7.7
4
Int
ArrivalCounterDown-
streamZone
8.0
8.7
4.0
4.15
This process data word is increased every time that ma-
terial being conveyed arrives in the downstream zone.
The overflow takes place when the value 65535 is
reached. The counter is reset to 0
9.0
9.7
5
Int
DisarrivalCounterDown-
streamZone
10.0
10.7
5.0
5.15
This process data word is increased every time that ma-
terial being conveyed leaves the downstream zone. The
overflow takes place when the value 65535 is reached.
The counter is reset to 0
11.0
11.7
25938274/EN – 01/2019
Summary of Contents for ECDriveS
Page 2: ...SEW EURODRIVE Driving the world...
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......