6
Appendix
Description of the access points
Manual – ECDriveS
®
37
Process
data word
[PI]
Data
type
Designation
Bytewise
notation
[byte.bit]
Wordwise
notation
[word.bit]
Description
Bool
3.0
1.8
RightSensorDetect
: If this bit is TRUE, a sensor was
detected on the right sensor port (PIN4)
Bool
3.1
1.9
LeftSensorDetect
: If this bit is TRUE, a sensor was de-
tected on the left sensor port (PIN4)
3.2
3.7
1.10
1.15
Res.
2
Byte
LeftCalcTemp (LeftM-
DRStatus)
4.0
4.7
2.0
2.15
Calculated temperature of the left motor roller in °C
Byte
ModuleTemp (LeftMDRStatus)
5.0
5.7
Temperature of the power section of the left drive axis,
measured in °C
3
Struct
Bool
LeftMDRDiagnostic (LeftM-
DRStatus)
6.0
3.0
Overheat
: Overtemperature fault
Bool
6.1
3.1
MaxTorque
: Motor at current limit
Bool
6.2
3.2
ShortCircuit
: Motor short circuit
Bool
6.3
3.3
MDRNotConnected:
No motor is connected to the mo-
tor port
Bool
6.4
3.4
Overload
: Overload detected: Speed lowered to <10%
of the setpoint speed due to the overload
Bool
6.5
3.5
Stalled
: Motor blockade detected
Bool
6.6
3.6
MDRBadHall:
Hall sensor fault
Bool
6.7
3.7
MDRNotUsed
: Interruptflag. Used to avoid a jam error
if, for example, material being conveyed is removed
from a removal buffer during ongoing operation
Bool
7.0
3.8
MDRStatus Bit1
: Description of the 2-bit coded
statuses
Bool
7.1
3.9
MDRStatus Bit2
: Description of the 2-bit coded
statuses
Bool
7.2
3.10
MDRinDOmode
: Motor port is connected to the digital
I/O mode
7.3
7.5
3.11
3.13
Res.
Bool
7.6
3.14
OverVoltage
: Overvoltage fault
Bool
7.7
3.15
LowVoltage
: Undervoltage fault
4
Byte
RightCalcTemp (RightM-
DRStatus)
8.0
8.7
4.0
4.7
Calculated temperature of the right motor roller in °C
Byte
ModuleTemp_1 (RightM-
DRStatus)
9.0
9.7
4.8
4.15
Temperature of the power section of the right drive axis
in °C
5
Struct
Bool
RightMDRDiagnostic (RightM-
DRStatus)
10.0
5.0
Overheat
: Overtemperature fault
Bool
10.1
5.1
MaxTorque
: Motor at current limit
Bool
10.2
5.2
ShortCircuit
: Motor short circuit
Bool
10.3
5.3
MDRNotConnected:
No motor is connected to the mo-
tor port
Bool
10.4
5.4
Overload
: Overload detected
Bool
10.5
5.5
Stalled
: Motor blockade detected
Bool
10.6
5.6
MDRBadHall:
Hall sensor fault
Bool
10.7
5.7
MDRNotUsed
: Interruptflag. Used to avoid a jam error
if, for example, material being conveyed is removed
from a removal buffer during ongoing operation
Bool
11.0
5.8
MDRStatus Bit1
: Description of the 2-bit coded
statuses
Bool
11.1
5.9
MDRStatus Bit2
: Description of the 2-bit coded
statuses
Bool
11.2
5.10
MDRinDOmode
: Motor port is connected to the digital
I/O mode
11.3
11.5
5.11
5.13
Res.
Bool
11.6
5.14
OverVoltage
: Overvoltage fault
Bool
11.7
5.15
LowVoltage
: Undervoltage fault
25938274/EN – 01/2019