Configuring PLC and master (DeviceNet scanner)
Project Planning and Startup on the DeviceNet Fieldbus
5.2
Configuring PLC and master (DeviceNet scanner)
The following samples refer to the usage of an Allen-Bradley-PLC ControlLogix 1756-
L61 together with the RSLogix 5000 programming software and the DeviceNet
RSNetWorx configuration software for DeviceNet.
After adding the DeviceNet Scanner to the I/O configuration, the file *.dnt containing the
DeviceNet configuration is selected. To view and edit the DeviceNet configuration, you
can launch RSNetWorx from this dialog (see following figure).
In RSNetWorx for DeviceNet (see following figure), either perform an online scan or add
the required devices to the graph by drag and drop. The address given under the icon
of the device must be equal to the MAC-ID set by the DIP switches of the DHF41B. If
the selection list does not include the required devices, corresponding EDS files have to
be registered via [Tools] / [Wizard].