Manual – MOVI-PLC® advanced DHF41B DeviceNet and PROFIBUS DP-V1 Fieldbus Interfaces
109
12
Communication via PROFIBUS DP/DP-V1
Operating MOVITOOLS® MotionStudio
12.6.3 Parameterize C2 master with SIMATIC NET
SIMATIC NET
versions and
operating system
Starting SIMATIC
NET and setting
the PG/PC
interface
Do the following to start SIMATIC NET:
1. From the Start menu of Windows, start the program "Set PG/PC Interface" under the
following menu item:
The "Set PG/PC interface" window opens:
2. Set the access path of the application as shown in the figure.
TIP
The following description might deviate slightly (in part due to the language) depending
on the SIMATIC NET version and the operating system in use.
This concerns the display and designations in windows as well as designations in the
menu path of the start menu.
12098AEN
TIP
If you cannot set the access path because the "Access point of the application" window
is disabled, then the reason is the following:
You have opened the "Set PG/PC interface" program from SIMATIC STEP 7 and have
therefore occupied the access path.
• Start the "Set PG/PC Interface" program from the Windows Start menu.