M
ANTEINANCE INTERVAL
Maintenance: The maintenance interval
on SESAMO’s automatism
is based on the intensity and term of use.
For systems with high traffic intensity (input airports, supermarkets, shopping centers, etc..) Or operating in particularly
harsh conditions should perform scheduled maintenance at six-month intervals agreed with a specialist.
For systems with low traffic intensity (small shops, offices, homes, operating rooms, etc.) should perform scheduled
maintenance at annual intervals agreed with a specialist.
.
MANTEINANCE
During a scheduled maintenance operation, carried out by an authorised technician, it is advisable to
carefully perform the checks and procedures listed below:
❑
Remove the mains power supply using the bipolar switch upstream from the automatism and the
switch on the automatism (switch “0
-
1”).
❑
Open the cap of the automatism.
❑
Disconnect the batteries (when are present).
❑
Check the tightening of the screws of the device components and screws to the structure of the
automation
❑
Check the tightening of the screws holding the arm to arm connection - these are screws with self-
locking treatment - replace them if they are loosened and tightened several times - using screws
provided by Sesamo.
❑
Check the wiring connections between accessories, sensors and electronic control unit.
❑
Reconnect the automatism to the mains power supply and the batteries.
❑
Check the smoothness of the frame, its general conditions (evaluate any misalignments caused by
impacts)
❑
Check the safety sensors (functionality and adjustment).
❑
Check the detection sensors (functionality and adjustment).
❑
Check the movement of the wings during braking and approach.
❑
Control the electric lock (functionality and regulation)
❑
Verify the correct selection of the operation logics.
❑
SmartPRO M check the efficiency of the batteries (when are present) by operating the installation
for a period without the mains power supply.
❑
Verify the movement, functionality and regulation in the low-
energy function (if it’s used).
❑
SmartPRO S: verify operation without power and eventually calibrate the spring.
❑
Close the cap and reassemble the arm
.
MODEL
SERIAL NUMBER
DATE
INTERVENTION
▪
SMARTPRO
▪
Maintenance Operation
▪
Intervention by Request